Results 11 to 20 of about 2,082,464 (295)
Electromagnetic interference (EMI) between implantable left ventricular assist devices and cardiac implantable electronic devices has been observed. We demonstrated the first case of EMI between a percutaneous ventricular assist device and an implantable
Kosuke Takahari, MD +9 more
doaj +2 more sources
Background We herein report the anesthetic management for extracardiac conduit–total cavopulmonary connection (EC-TCPC) for weaning from an extracorporeal right ventricular assist device (RVAD) in a patient with an implantable left ventricular assist ...
Naka Kida +4 more
doaj +2 more sources
Cardiogenic shock has a poor prognosis with established treatment strategies. We report a 62 years old man with heart failure exacerbating into refractory cardiogenic shock successfully treated with the combination of a percutaneous left ventricular ...
Pettersen Reidar +6 more
doaj +2 more sources
Background: Limited data exist regarding complication rates of implantable cardioverter-defibrillators (ICD) and cardiac resynchronization therapy devices (CRT-D) in patients with left ventricular assist devices (LVAD).
Ashwin Ravichandran, MD +13 more
doaj +2 more sources
This study sought to determine the indications, characteristics, and outcomes of cardiovascular implantable electronic device (CIED) surgery in patients with LVAD.Many patients with a left ventricular assist device (LVAD) will require implantable cardioverter-defibrillator generator change or device revision or are candidates for de novo implantable ...
Daniel Friedman +2 more
exaly +3 more sources
Thoratec Implantable Ventricular Assist Device: The Papworth Experience [PDF]
The Thoratec (Thoratec Corp, Pleasanton, Calif) implantable ventricular assist device (IVAD) can be used for univentricular or biventricular support. The objective of this study is to review the 5-year experience of bridging patients to heart transplantation with this device in a single center.
Stephen Large +2 more
exaly +3 more sources
BackgroundVentricular arrhythmias are common in patients with left ventricular assist devices (LVADs) but are often hemodynamically tolerated. Optimal implantable cardioverter defibrillator (ICD) tachy‐programming strategies in patients with LVAD have ...
Travis D. Richardson +9 more
doaj +3 more sources
Catheterization of a patient with implantable left ventricular assist device and acute pump failure [PDF]
Jerzy Demkow +4 more
doaj +2 more sources
Minimally invasive ventricular assist device implantation [PDF]
Durable mechanical circulatory support (MCS) systems are established therapy option in patients with end-stage heart failure, with increasing importance during the last years due to donor organ shortage. Left ventricular assist devices (LVADs) are traditionally implanted through median sternotomy (MS).
Al-Naamani, Ameen +12 more
openaire +2 more sources
We evaluated an independently developed novel percutaneous implantable left ventricular assist device for resuscitation in a pig model of ventricular fibrillation cardiac arrest.
Zongtao Wang +9 more
doaj +1 more source