Results 21 to 30 of about 25,651 (184)

First Case Report of Electromagnetic Interference Between Percutaneous Ventricular Assist Device and Implantable Cardioverter-Defibrillator

open access: yesJACC: Case Reports, 2023
Electromagnetic interference (EMI) between implantable left ventricular assist devices and cardiac implantable electronic devices has been observed. We demonstrated the first case of EMI between a percutaneous ventricular assist device and an implantable
Kosuke Takahari, MD   +9 more
doaj   +1 more source

Diagnosis of atrial fibrillation in heart failure patients with implantable cardioverter defibrillator or cardiac resynchronisation therapy

open access: yesArchives of Medical Science, 2021
Introduction Implantable cardioverter defibrillators register various types of arrhythmias. Thus they can be exploited to better identify patients with atrial fibrillation episodes and increase the proportion of patients who may benefit from ...
Barbara Dominik   +4 more
doaj   +1 more source

Stepwise cardiac rehabilitation adjustment after exercise-induced implantable cardioverter defibrillator shock: a case report

open access: yesJournal of Rehabilitation Medicine - Clinical Communications
Objective: To report an in-hospital cardiac rehabilitation strategy after exercise-induced implantable cardioverter defibrillator shock. Case report: A 72-year-old man with heart failure, peripheral artery disease, a history of percutaneous coronary ...
Hidetoshi Yanagi   +4 more
doaj   +1 more source

S-ICD oversensing detected by remote monitoring using a new atrial fibrillation diagnostic algorithm

open access: yesIndian Pacing and Electrophysiology Journal, 2018
A 64-year-old male with a high body mass index, and subcutaneous implantable cardioverter defibrillator, (S-ICD) presented with a remote transmission of inappropriately diagnosed AF episodes, due to oversensing of P and T waves.
Christopher Monkhouse   +2 more
doaj   +1 more source

Brugada Syndrome: New Implications for Heterozygous Carriers of the Pathogenic SCN5A c.689T>C(p.Ile230Thr) Variant

open access: yesAmerican Journal of Medical Genetics Part A, EarlyView.
ABSTRACT Pathogenic variants in the SCN5A gene and its subunits have been identified in individuals with Brugada Syndrome. One such SCN5A variant, c.689T>C(p.Ile230Thr), was previously reported as disease‐causing only in homozygous individuals, with heterozygous carriers being unaffected.
Shayla Shojaat   +2 more
wiley   +1 more source

S-ICD Implantation "Tips and Tricks"

open access: yesReviews in Cardiovascular Medicine, 2023
An implantable cardioverter-defibrillator (ICD) was developed to provide protection against sudden cardiac death. Despite being effective in terminating ventricular arrhythmias, traditional transvenous ICDs appeared over time to have certain limitations ...
Szymon Budrejko   +2 more
doaj   +1 more source

Impact of Rapid Exome Sequencing on Pediatric Patients With Cardiomyopathy and Acute Heart Failure

open access: yesAmerican Journal of Medical Genetics Part A, EarlyView.
ABSTRACT Few studies describe the impact of rapid exome sequencing (ES) on pediatric cardiomyopathy in urgent clinical settings. Here, we retrospectively report the impact of rapid singleton ES in pediatric patients presented with acute heart failure and isolated cardiomyopathy or myocarditis, between 2021 and 2023 at a single tertiary care center.
Tameemi Abdalla Moady   +10 more
wiley   +1 more source

Subcutaneous Implantable Cardioverter Defibrillator: Early Experience

open access: yesBrazilian Journal of Cardiovascular Surgery
Introduction: The implantable cardioverter defibrillator had been increasing the survival of patients at high risk for sudden cardiac death. The subcutaneous implantable cardioverter defibrillator was developed to mitigate the complications inherent to ...
Fernando Sérgio Oliva Souza   +6 more
doaj   +1 more source

Dental management of a patient fitted with subcutaneous Implantable Cardioverter Defibrillator device and concomitant warfarin treatment

open access: yesSaudi Dental Journal, 2015
Automated Implantable Cardioverter Defibrillators (AICD), simply known as an Implantable Cardioverter Defibrillator (ICD), has been used in patients for more than 30 years.
Altaf Hussain Shah   +2 more
doaj   +1 more source

Long‐Term Impact of Prosthesis‐Patient Mismatch After Transcatheter Aortic Valve Replacement in Patients With Small Aortic Annuli

open access: yesCatheterization and Cardiovascular Interventions, EarlyView.
ABSTRACT Background Prosthesis‐patient mismatch (PPM) remains common following transcatheter aortic valve replacement (TAVR) and is associated with worse clinical outcomes. PPM is of particular concern in small aortic annuli (SAA). Aims To compare the incidence, predictors, and long‐term impact of PPM in SAA TAVR.
Itamar Loewenstein   +9 more
wiley   +1 more source

Home - About - Disclaimer - Privacy