Results 71 to 80 of about 27,813 (176)
Immune checkpoint inhibitor (ICI)‐associated myocarditis has emerged as a severe and clinically complex immune‐related toxicity that poses significant challenges for therapeutic decision‐making in routine cardio‐oncological care. High‐dose corticosteroids remain the first‐line therapy, yet their timing, dosage and tapering require careful clinical ...
Raluca I. Mincu +10 more
wiley +1 more source
The first cardioverter defibrillator implanted in Central Africa
Sudden cardiac deaths, which account for approximately 350 000 deaths each year, is a major health care problem. Antiarrhythmic drugs have not been reliable in preventing sudden cardiac death. Although -blockers, angiotensin-converting enzyme inhibitors,
Tantchou Tchoumi Jacques Cabral +2 more
doaj +1 more source
Arrhythmias associated with immune checkpoint inhibitor therapy—A clinical perspective
Immune checkpoint inhibitors (ICIs) have transformed cancer therapy but are associated with a growing spectrum of cardiovascular immune‐related adverse events. Among these, arrhythmias represent a rare yet potentially life‐threatening complication. ICI‐induced arrhythmias encompass a wide clinical spectrum, including atrial arrhythmias, conduction ...
Dong Wang +4 more
wiley +1 more source
Smartphone heart monitors in pediatric CIEDs: A pilot study. Smartphone heart monitors did not induce EMI in children with CIEDs, enabling reliable heart rate measurement and accurate identification of ventricular non‐captures. ABSTRACT Background Portable heart monitors enable on‐demand electrocardiogram (ECG) recordings and enhance symptom‐rhythm ...
Chun‐Lok Ho +3 more
wiley +1 more source
Risks of Appropriate Implantable Cardioverter Defibrillator Therapy and Hospitalization Are Increased Around Device-Detected Atrial High-Rate Episodes Longer Than 6 min. [PDF]
Device‐detected atrial high‐rate episodes (AHREs) lasting ≥ 6 min identify a transient period of increased clinical risk in ICD patients. During the 60‐day peri‐AHRE period, risks of appropriate ICD shock, any appropriate ICD therapy, and cardiac hospitalization were significantly increased.
Nørgaard N +3 more
europepmc +2 more sources
Mental Disorders After Cardiac Implantable Electronic Device Implantation in Young Individuals
Background Increasing use of cardiac implantable electronic devices (CIEDs) has raised concerns about psychological distress in young adults. We evaluated the risk of incident mental disorders after CIED implantation.
Young‐Hae Go +9 more
doaj +1 more source
ABSTRACT Introduction Patients with repaired tetralogy of Fallot (rTOF) remain at risk of ventricular tachycardia (VT). This risk is most commonly related to slow conduction within the septal isthmus, which is defined as the region between the ventricular septal defect (VSD) patch and adjacent valvular annuli.
Yuki Matsuoka +8 more
wiley +1 more source
Diagnostic yield and therapeutic impact varied substantially according to the indication for implantation. Actionable diagnoses were concentrated in the early follow‐up period for syncope and palpitations, whereas late atrial fibrillation detection after cryptogenic stroke could still modify antithrombotic management. In contrast, patients with Brugada
Luigi Cocchiara +17 more
wiley +1 more source
Background Although the availability of electrophysiology technologies has expanded in the United States, little is known about how sociodemographic factors influence their use. This national study of the Medicare population aims to (1) examine trends in
Frans Serpa +8 more
doaj +1 more source
The study examines 76 patients of the German multicenter study COGIA with suspected BrS in 12 centers in Germany. Thirty‐nine patients met the current ESC diagnostic criteria, 34 of whom met the Shanghai Score criteria. Four major arrhythmic events (ACA, SCD, appropriate ICD shock) occurred in the cohort (5.3%), all in the group of patients fulfilling ...
Lea Lippert +35 more
wiley +1 more source

