Biofilm Analysis of Retrieved Dental Implants after Different Peri-Implantitis Treatments [PDF]
The aim of the current study was to analyse the planktonic growth of Streptococcus mutans on the surfaces of three implants retrieved after three different peri-implantitis treatments. Three implants from a male patient with high levels of bone loss were
Thaise C. Geremias +5 more
doaj +2 more sources
The Effect of Implantoplasty on the Fatigue Behavior and Corrosion Resistance in Titanium Dental Implants [PDF]
Implantoplasty is a technique increasingly used to remove the biofilm that causes peri-implantitis on dental implants. This technique of mechanization of the titanium surface makes it possible to eliminate bacterial colonies, but it can generate ...
Fonseca D +6 more
europepmc +7 more sources
The Impact of Operator Access on Implant Surface Roughness Following Implantoplasty Procedures: A Laboratory Study [PDF]
Objectives To evaluate the influence of operator access on surface roughness parameters and material loss following implantoplasty (IP). Material and Methods A total of 42 dental implants were utilized in this study, and three different implant designs ...
Eamonn Donohoe +5 more
doaj +2 more sources
The Novel iMPACT Tool and Quadrant Protocol for Peri-Implantitis: Surface Refinement and Re-Osseointegration Validated by SEM/EDS and Long-Term Clinical Case Reports [PDF]
Background and Objectives: The goal of this study was to introduce a novel device, the iMPACT implant planer, designed to machine (create a complete smooth surface) contaminated implant surfaces intraorally, promoting peri-implant tissue healing and ...
Gustavo Vicentis Oliveira Fernandes +4 more
doaj +2 more sources
Assessing the Impact of Various Decontamination Instruments on Titanium and Zirconia Dental Implants: An In Vitro Study [PDF]
This study investigates the impact of various instrumentation techniques on material removal and surface changes in titanium (Ti)- and zirconia (Zr) implant discs.
Louisa Vierling +4 more
doaj +2 more sources
The effect of standardised implantoplasty protocol on titanium surface roughness: an in-vitro study [PDF]
: To analyse the changes of surface characteristics of machined and moderately roughened titanium disks following a standardised implantoplasty protocol.
Andrew TAWSE-SMITH +4 more
doaj +4 more sources
Peri-Implant Soft Tissue Phenotype Remodeling Following Peri-Implantitis Surgery: A Prospective Profilometric Analysis. [PDF]
ABSTRACT Aim To characterize longitudinal changes in peri‐implant soft tissue phenotype following surgical therapy of peri‐implantitis. Materials and Methods Twenty‐one patients with superimposable intraoral scan datasets at four timepoints—pre‐operative (T0), intra‐operative (T1), 3‐month (T2), and 12‐month (T3) follow‐up—were included.
Choi HS +6 more
europepmc +2 more sources
In vitro evaluation of different protective techniques to reduce titanium particle contamination during implantoplasty. [PDF]
OBJECTIVES Our aim is to study titanium remains in a bone model during standardized implantoplasty under different isolation and protective modalities.
Platt A +5 more
europepmc +2 more sources
Cytocompatibility and Microbiological Effects of Ti6Al4V Particles Generated During Implantoplasty on Human Fibroblasts, Osteoblasts, and Multispecies Oral Biofilm [PDF]
Luis Delgado +2 more
exaly +2 more sources
Efficacy of implantoplasty in management of peri-implantitis: A systematic review
Aim: Peri-implantitis causes progressive loss of the supporting bony structure around the dental implant. Implantoplasty mechanically removes contaminated threads to achieve smoother implant surface thus reducing the bacterial load enabling fibroblastic growth to stimulate the healing effect.
Dasgupta, Dolanchanpa +3 more
openaire +2 more sources

