Physics, 1933
Three different types of low voltage circuits suitable for supplying impulse voltages in oscillographic work are discussed. These circuits use Thyratrons as the connecting and timing switches in place of the spark gaps ordinarily employed in transient investigations. Charged condensers are used as the source of voltage.
openaire +1 more source
Three different types of low voltage circuits suitable for supplying impulse voltages in oscillographic work are discussed. These circuits use Thyratrons as the connecting and timing switches in place of the spark gaps ordinarily employed in transient investigations. Charged condensers are used as the source of voltage.
openaire +1 more source
Effects of impulse surge voltages on alternators
2001 IEEE Porto Power Tech Proceedings (Cat. No.01EX502), 2002We consider the impulse surge voltages acting on alternators running in the block with the elevating transformer. The alternators' insulation is not stable, particularly when the block alternators are placed in more severe conditions because the surge voltage waves coming from the line and through the step-up transformer have a direct effect on them ...
T. Otmane-Cherif +2 more
openaire +1 more source
The effects of impulse voltages on transformer windings
Journal of the Institution of Electrical Engineers, 1937The effects of the application of impulse voltages of varied wave-shapes to transformers are analysed theoretically and experimentally. Single and multiple transients have been considered, and oscillographic tests have been made on model transformers of different winding characteristics, and on both single-phase and 3-phase transformers.
T.E. Allibone, D.B. McKenzie, F.R. Perry
openaire +1 more source
Peak-voltage measurements of standard impulse voltage waves
Proceedings of the IEE Part C: Monographs, 1956The frequency spectrum of a 1/50 microsec impulse wave is obtained by the use of the Fourier transform. The corresponding frequency spectrum of the output from a simple capacitance potential divider, suitable for use up to 300 kV, is calculated from the input frequency spectrum for a 1/50 microsec wave and the frequency response of the divider ...
openaire +1 more source
The measurement of the magnitude of impulse voltages using voltage comparators
Journal of Physics E: Scientific Instruments, 1971A digital peak voltmeter is described which determines the unknown voltage by comparing it with each of 100 known constant voltages in turn. Each constant voltage exceeds its predecessor by a fixed amount. Despite the large number of reference voltages employed, only ten comparators are used.
openaire +1 more source
Measurements on impulse voltages with a ballistic galvanometer
Journal of the Institution of Electrical Engineers - Part II: Power Engineering, 1942Simple Circuits are described whereby measurements of the crest value and time of duration of the transient voltages used in impulse testing may be made with a ballistic galvanometer. Both methods of measurement have been compared with the results obtained simultaneously by a high-speed cathode-ray oscillograph.
openaire +1 more source
High-Impulse Current and Voltage Measurement
IEEE Transactions on Instrumentation and Measurement, 1970This paper is a survey of methods of high-impulse current and voltage measurement. Typically, such measurement techniques must now include capabilities for measuring high-energy impulses having peak powers as high as many megawatts, currents as high as many mega-amperes, or voltages as high as several megavolts, with rise times as short as a fraction ...
openaire +1 more source
High-Voltage Impulse Converter
2023 International Conference on Industrial Engineering, Applications and Manufacturing (ICIEAM), 2023Dmitriy Sorokin +2 more
openaire +1 more source
IEEE Transactions on Dielectrics and Electrical Insulation, 2022
Xuanrui Zhang, Xutao Han, Yidan Hu
exaly
Xuanrui Zhang, Xutao Han, Yidan Hu
exaly