2019
In power supply networks for the transmission and distribution of electrical energy at high voltage, transient voltages of more than 1 MV can occur due to lightning or switching operations. Because of their high magnitudes and short rise times, ranging from a fraction of a microsecond to milliseconds, the overvoltages cause enhanced stress on the ...
openaire +1 more source
In power supply networks for the transmission and distribution of electrical energy at high voltage, transient voltages of more than 1 MV can occur due to lightning or switching operations. Because of their high magnitudes and short rise times, ranging from a fraction of a microsecond to milliseconds, the overvoltages cause enhanced stress on the ...
openaire +1 more source
Electroluminescence in polyethylene terephthalate (PET) (impulse voltage)
Conference on Electrical Insulation & Dielectric Phenomena - Annual Report 1981, 1981Electroluminescence was observed in PET when an impulse voltage was applied. The electroluminescence depended on the electrode material of the cathode and showed only a weak temperature dependence and a superlinear dependence on the electric field. The spectrum of the electroluminescence was identical with that of the photoluminescence originating from
Kenzo Kojima +2 more
openaire +1 more source
The measurement of short-duration impulse voltages
IEEE Transactions on Communication and Electronics, 1963A description is given of a very-small-impulse voltage divider which is insulated by compressed gas. The divider was designed for the measurement of steep-front impulse waves, and its errors have been evaluated by the step-response method, using a pressurized sphere gap.
Creed, F. C., Collins, M. M.C.
openaire +2 more sources
Electroluminescence in polyethylene subjected to impulse voltages
IEEE Transactions on Dielectrics and Electrical Insulation, 1998Electroluminescence (EL) from HDPE (high-density polyethylene) films subjected to repetitive rectangular-shaped impulse voltages has been investigated at electric fields
T. Mizuno +7 more
openaire +1 more source
Physics, 1933
Three different types of low voltage circuits suitable for supplying impulse voltages in oscillographic work are discussed. These circuits use Thyratrons as the connecting and timing switches in place of the spark gaps ordinarily employed in transient investigations. Charged condensers are used as the source of voltage.
openaire +1 more source
Three different types of low voltage circuits suitable for supplying impulse voltages in oscillographic work are discussed. These circuits use Thyratrons as the connecting and timing switches in place of the spark gaps ordinarily employed in transient investigations. Charged condensers are used as the source of voltage.
openaire +1 more source
Measurement of High-Voltage Impulses
2013For conventional measurement of lightning, switching, chopped and oscillating impulse voltages, measuring systems with high-voltage dividers up to several megavolts have been employed for decades. They are classified as resistive, capacitive and resistive-capacitive voltage dividers.
openaire +1 more source
Acoustic measurement at voltage impulse test
CEIDP '05. 2005 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, 2005., 2005Power transformers and transformers generally are key components of electricity transmission and distribution. Service life and quality of transformer are to a great extent dependent on working of insulating system of this device. Insulating system structure, used materials (for example transformer oil, cable paper, cellulose trafoboard, epoxy resin ...
J. Doleza +4 more
openaire +1 more source
Peak-voltage measurements of standard impulse voltage waves
Proceedings of the IEE Part C: Monographs, 1956The frequency spectrum of a 1/50 microsec impulse wave is obtained by the use of the Fourier transform. The corresponding frequency spectrum of the output from a simple capacitance potential divider, suitable for use up to 300 kV, is calculated from the input frequency spectrum for a 1/50 microsec wave and the frequency response of the divider ...
openaire +1 more source
The measurement of the magnitude of impulse voltages using voltage comparators
Journal of Physics E: Scientific Instruments, 1971A digital peak voltmeter is described which determines the unknown voltage by comparing it with each of 100 known constant voltages in turn. Each constant voltage exceeds its predecessor by a fixed amount. Despite the large number of reference voltages employed, only ten comparators are used.
openaire +1 more source
The effects of impulse voltages on transformer windings
Journal of the Institution of Electrical Engineers, 1937The effects of the application of impulse voltages of varied wave-shapes to transformers are analysed theoretically and experimentally. Single and multiple transients have been considered, and oscillographic tests have been made on model transformers of different winding characteristics, and on both single-phase and 3-phase transformers.
T.E. Allibone, D.B. McKenzie, F.R. Perry
openaire +1 more source