Inappropriate shocks following recent generator replacement

Herzschrittmachertherapie + Elektrophysiologie, 2023
In a 64-year-old male patient with an implantable cardioverter defibrillator (ICD) for secondary prevention of sudden cardiac death, a shock occurred some months after generator exchange and downgrade to a single-chamber system. Careful analysis of the stored electrogram revealed a rare cause that could be confirmed at the time of operative revision.
Sherien, Samy Awad   +3 more
openaire   +2 more sources

Inappropriate shocks in the subcutaneous ICD: Incidence, predictors and management

International Journal of Cardiology, 2015
The entirely subcutaneous implantable cardioverter-defibrillator (S-ICD) eliminates the need for transvenous leads, and therefore has the potential to improve lead-longevity and reduce lead-related complications. The S-ICD has a morphology-based sensing algorithm of which inappropriate shocks have been reported.We analyzed the incidence, predictors and
Olde Nordkamp, Louise R A   +11 more
openaire   +3 more sources

Inappropriate defibrillator shocks and mortality

Heart, 2013
Despite the established survival benefits of implantable cardioverter defibrillators (ICD) in patients with ischaemic cardiomyopathy and other forms of cardiomyopathies, a major limitation of this technology remains the delivery of inappropriate shocks for reasons other than life-threatening ventricular tachycardia or ventricular fibrillation ...
openaire   +2 more sources

Biventricular Implantable Cardioverter Defibrillator and Inappropriate Shocks

Journal of Cardiovascular Electrophysiology, 2003
Biventricular ICD and Inappropriate Shocks. A 53‐year‐old man with nonischemic cardiomyopathy underwent implantation of a biventricular implantable cardioverter defibrillator (ICD) for symptomatic ventricular tachycardia. He received five shocks while attempting to exercise, 48 hours after implantation.
Komandoor, Srivathsan   +2 more
openaire   +2 more sources

Inappropriate Shock Therapy in a Heart Failure Defibrillator

Pacing and Clinical Electrophysiology, 2001
BETTS, T.R., et al.: Inappropriate Shock Therapy in a Heart Failure Defibrillator. A 63‐year‐old male with dilated cardiomyopathy underwent implantation of a “heart failure” defibrillator capable of biventricular pacing. He received an inappropriate shock 5 hours after the procedure.
Betts, Tim R.   +3 more
openaire   +3 more sources

Is Inappropriate Implantable Defibrillator Shock Therapy Predictable?

Journal of Interventional Cardiac Electrophysiology, 2003
To identify implantable cardioverter defibrillator (ICD) patients who are at risk of receiving inappropriate shock.Inappropriate ICD shock, usually from atrial fibrillation (AF) or sinus tachycardia (ST), is a common problem. We hypothesized that clinical variables would predict which patients with single chamber ICDs would be more likely to receive ...
Kumaraswamy, Nanthakumar   +7 more
openaire   +2 more sources

Causes and Prevention of Inappropriate Implantable Cardioverter-Defibrillator Shocks

Cardiac Electrophysiology Clinics, 2018
Use of implantable cardioverter-defibrillators as a primary prevention therapy has been shown to reduce mortality in patients after cardiac arrest and also with left ventricular systolic dysfunction. Yet, inappropriate shocks are variably reported and associated with a reduction in quality of life.
Nitin, Kulkarni, Mark S, Link
openaire   +2 more sources

Inappropriate implantable cardioverter-defibrillator shock in unusual circumstances

Acta Cardiologica, 2016
(2016). Inappropriate implantable cardioverter-defibrillator shock in unusual circumstances. Acta Cardiologica: Vol. 71, No. 3, pp. 369-370.
M-C-B, Suran   +3 more
openaire   +2 more sources

Inappropriate ICD Shocks Caused by External Electrical Noise

New England Journal of Medicine, 2009
To the Editor: Because of the growing number of patients worldwide who are receiving implantable cardioverter–defibrillators (ICDs)1 and the increasing number of indications for their use, physicia...
Anna Margrethe, Thøgersen   +2 more
openaire   +2 more sources

[Inappropriate ICD shocks after collision with a pole].

Nederlands tijdschrift voor geneeskunde, 2016
A 60-year-old man experienced inappropriate ICD shocks after collision with a pole. Cine-fluoroscopy demonstrated lead fracture of the proximal lead, which was not so clearly visible on the chest radiograph. He underwent lead extraction and implantation of a new ICD system.
Yap, Sing   +2 more
openaire   +2 more sources