Results 31 to 40 of about 35,807 (151)
Background: Inappropriate empirical antimicrobial therapy for sepsis or septic shock patients is independently linked to higher mortality rates. This study aims to evaluate the impact of inappropriate empirical antibiotic therapy on mortality and length
Yousif B. Hamadalneel +3 more
doaj +1 more source
Sensing and defibrillation threshold for a S‐ICD are impacted by positioning at implant or revision. The intermuscular pocket prevents device migration and provides appropriate, stable sensing vectors.
Jeko M. Madjarov +4 more
doaj +1 more source
Background Septic shock is a life-threatening condition and one of the most common causes of acute kidney injury. Polymyxin B-immobilized fiber column direct hemoperfusion (PMX-DHP) is used to reduce endotoxin levels in blood.
Hisato Shima +17 more
doaj +1 more source
Background Pharmacological treatment of atrial fibrillation (AF) in the setting of Brugada syndrome (BrS) is challenging. In addition, patients with BrS with an implantable cardioverter‐defibrillator (ICD) might experience inappropriate shocks for fast ...
Antonio Bisignani +19 more
doaj +1 more source
Background Persistent atrial fibrillation may lead to a higher probability of inappropriate shocks in heart failure patients with an implantable cardioverter‐defibrillator (ICD). The aim of this study was to evaluate the impact of His‐Purkinje conduction
Songjie Wang +7 more
doaj +1 more source
ICD Lead Dislodgement and Inappropriate ICD Shocks [PDF]
Figure 1. (a) Chest radiograph showing the ICD generator (black star), ICD lead (arrowhead), and the two coils (arrows) for providing the electric shock. The superior vena cava coil (white arrows) is displaced into the left subclavian vein and the right ventricular lead (black arrows) is displaced into the right atrium, directed toward the region of ...
openaire +2 more sources
Implantable cardioverter defibrillator (ICD) shocks are always a matter of anxiety and concern for both patient and clinician. We report a case of ischemic cardiomyopathy who reported to us after receiving two shocks within 48 hours.
Sanjeev S Mukherjee +2 more
doaj +1 more source
Inappropriate Extravascular ICD Shock Due to Wet Car Seat
Inappropriate shocks from an Intracardiac defibrillator are associated with increased mortality and may be caused by external electromagnetic interference.
Stian Ross, MD, PhD +2 more
doaj +1 more source
BackgroundIn US clinical practice, many patients who undergo placement of an implantable cardioverter‐defibrillator (ICD) for primary prevention of sudden cardiac death receive dual‐chamber devices.
Pamela N. Peterson +18 more
doaj +1 more source
SMART pass will prevent inappropriate operation of S‐ICD
Background Compared to screening ECG before implantation of a subcutaneous implantable cardioverter‐defibrillator (S‐ICD), selectable vectors without T‐wave oversensing increase after S‐ICD implantation. Newer algorithms have recently become available to
Motomi Tachibana +7 more
doaj +1 more source