Results 231 to 240 of about 154,924 (355)

Prevalence of Buccal Ridge Concavities Following Implant Placement With Contour Bone Augmentation: A Cross‐Sectional Study

open access: yesClinical Oral Implants Research, EarlyView.
ABSTRACT Objectives To evaluate the long‐term prevalence of buccal ridge concavity (BRC) following implant placement with simultaneous contour bone augmentation (CBA). Methods Adult patients with at least one single‐tooth non‐molar implant‐supported prosthesis and no diagnosis of peri‐implantitis were included in this exploratory cross‐sectional study.
Sophia E. Vollath   +7 more
wiley   +1 more source

Accuracy (Trueness and Precision) of the Calibrated Intraoral Scan Protocol: An In Vitro Comparison of Three Scan Calibrator Designs In an Edentulous Implant Model

open access: yesClinical Oral Implants Research, EarlyView.
ABSTRACT Objectives To introduce a universal scan calibrator (SC) and to evaluate its accuracy in the calibrated intraoral scan protocol (CISP) by comparison with two previously published SCs. Materials and Methods Three SCs were evaluated on an edentulous implant model containing six scan bodies (SBs) positioned at the screw‐retained abutment (SRA ...
Shengtao Yang   +7 more
wiley   +1 more source

MSX1 and PAX9 Polymorphisms and Their Association With Lateral Incisor Morphology in Patients With Maxillary Canine Impaction. [PDF]

open access: yesMed Sci Monit
Todorović A   +8 more
europepmc   +1 more source

Prevalence and Risk Indicators of Peri‐Implant Diseases in China: A Multicenter Cross‐Sectional Study

open access: yesClinical Oral Implants Research, EarlyView.
ABSTRACT Aim To evaluate the prevalence and risk indicators of peri‐implant diseases in a randomly selected Chinese population. Materials and Methods A total of 819 patients with 1412 implants from eight university hospital databases were clinically and radiographically evaluated along with medical records to assess the prevalence of peri‐implant ...
Xinbo Yu   +9 more
wiley   +1 more source

The Effect of Crown Height and Retentive Height of Abutment on the Fracture Resistance of Fatigued Monolithic Zirconia Anterior Implant Crowns—An In Vitro Study

open access: yesClinical Oral Implants Research, EarlyView.
ABSTRACT Objectives This laboratory study investigated the effect of two different retentive heights of Ti‐base abutments (3.5 and 5.5 mm) and crown heights (13 and 16 mm) on the load at failure and survival of monolithic zirconia implant‐supported crowns replacing a maxillary central incisor.
Esha Zahid   +5 more
wiley   +1 more source

A 3D comparison of planned versus achieved anterior tooth position in clear aligner treatment. [PDF]

open access: yesSci Rep
Saif BS   +9 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy