Results 291 to 300 of about 5,341,111 (402)

Modelling of a double‐scattering proton therapy nozzle using the FLUKA Monte Carlo code and analysis of linear energy transfer in patients treated for prostate cancer

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The dose‐averaged linear energy transfer (LETD) in proton therapy (PT) has in pre‐clinical studies been linked to the relative biological effectiveness (RBE) of protons. Until recently, the most common PT delivery method in prostate cancer has been double‐scattered PT, with LETD only available through dedicated Monte Carlo (MC ...
Rasmus Klitgaard   +7 more
wiley   +1 more source

Impact of enhanced leaf model on dose calculation accuracy in single‐isocenter multitarget stereotactic radiosurgery treatments

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Single‐isocenter multitarget (SIMT) radiosurgery has become increasingly popular as advancement in planning and delivery systems have made this approach clinically viable. With targets varying in size and distance from isocenter, SIMT plans are highly complex with dynamic multileaf collimator (MLC) motion.
Hem Moktan   +3 more
wiley   +1 more source

Frequency Index Modulation for Low Complexity Low Energy Communication Networks

open access: gold, 2017
Ebrahim Soujeri   +3 more
openalex   +1 more source

Evaluating the use of diagnostic CT with flattening filter free beams for palliative radiotherapy: Dosimetric impact of scanner calibration variability

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Palliative radiotherapy comprises a significant portion of the radiation treatment workload. Volumetric‐modulated arc therapy (VMAT) improves dose conformity and, in conjunction with flattening filter free (FFF) delivery, can decrease treatment times, both of which are desirable in a population with a high probability of retreatment ...
Madeleine L. Van de Kleut   +2 more
wiley   +1 more source

Commissioning of Halcyon enhanced leaf model in the Eclipse treatment planning system: Focus on simple slit fields and VMAT dose calculation

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The dual‐layer multileaf collimator (MLC) in Halcyon adds complexities to the dose calculation process owing to the variability of dosimetric characteristics with leaf motion. Recently, an enhanced leaf model (ELM) was developed to refine the MLC model in the Eclipse treatment planning system. This study investigates the performance of
Ryohei Miyasaka   +6 more
wiley   +1 more source

Stereotactic radiotherapy for metastatic brain tumors: A comparative analysis of dose distributions among VMAT, Helical TomoTherapy, CyberKnife, Gamma Knife, and ZAP‐X

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract This study evaluates various radiotherapy techniques for treating metastatic brain tumor (BT), focusing on non‐coplanar volumetric modulated arc radiotherapy (NC‐VMAT), coplanar VMAT (C‐VMAT), Helical TomoTherapy (HT), CyberKnife (CK), Gamma Knife (GK), and ZAP‐X.
Toshihiro Suzuki   +9 more
wiley   +1 more source

Home - About - Disclaimer - Privacy