Results 61 to 70 of about 6,720,470 (295)

Phase Boundary Engineering of Co2P‐CoP Branched Nanoparticles Enhances Cobalt Oxidation for Oxygen Evolution Electrocatalysis

open access: yesAdvanced Materials, EarlyView.
Phase boundaries between Co2P and CoP are constructed through a controlled transformation of Co to Co2P‐CoP branched nanoparticles. The polycrystalline mixed‐phase Co2P‐CoP branches are enriched with phase boundaries that stabilize Co active sites for OER. This work highlights phase boundary engineering as a powerful approach to tailor active sites and
Zeno R. Ramadhan   +10 more
wiley   +1 more source

Leaftronics: Bio‐Fractal Scaffolds From Leaf Venation for Low‐Waste Electronics

open access: yesAdvanced Materials, EarlyView.
“Leaftronics” transforms naturally evolved leaf venation into quasi‐fractal scaffolds for sustainable electronics. Polymer‐infiltrated leaf skeletons can be used to fabricate ultra‐smooth, reflow‐ and thin‐film‐compatible decomposable substrates, while making the same lignocellulose networks conducting results in flexible transparent electrodes.
Rakesh Rajendran Nair   +3 more
wiley   +1 more source

INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY FOR THE DETERMINATION OF 237Np IN SPENT NUCLEAR FUEL SAMPLES BY ISOTOPE DILUTION METHOD USING 239Np AS A SPIKE

open access: yesNuclear Engineering and Technology, 2013
A determination method for 237Np in spent nuclear fuel samples was developed using an isotope dilution method with 239Np as a spike. In this method, inductively coupled plasma mass spectrometry (ICP-MS) was taken for the 237Np instead of the previously ...
KIHSOO JOE   +5 more
doaj   +1 more source

Unveiling Exsolution‐Induced Giant Electronic and Magnetic Property Changes in Non‐Stoichiometric Titanate Perovskite Thin Films

open access: yesAdvanced Materials, EarlyView.
A giant insulator to metal transition and emergent superparamagnetism are revealed by nanoparticle exsolution in non‐stoichiometric titanate perovskite thin films. By combining transport, synchrotron spectroscopy, and first‐principles calculations, this work reveals how defect reconfiguration and lattice reconstruction fundamentally reshape electronic ...
Sungil Kim   +11 more
wiley   +1 more source

Thorium determination in seawater by inductively coupled plasma mass spectrometry: Method development and oceanographic applications

open access: yesTalanta Open
Thorium isotopes in the ocean (including radiogenic isotopes and terrigenous-derived 232Th) serve as key tracers for studying land-derived material transport. While high-sensitivity and high-resolution inductively coupled plasma mass spectrometry (ICP-MS)
Yingjie Zou   +4 more
doaj   +1 more source

Matrix Effects in Inductively Coupled Plasma Mass Spectrometry

open access: yesAnalytical Sciences, 1987
Suppression of analyte signals by various concomitant elements was investigated. In addition to the ionization interference by easily ionizable elements reported previously, signal suppression by heavy matrix elements was found to be significant. The interference trend followed the order of atomic weight of the matrix elements, i.e., the larger the ...
KAWAGUCHI, Hiroshi   +4 more
openaire   +2 more sources

Accelerated Materials Discovery Through In Situ X‐ray Diffraction: Solvothermal Formation of PdxMy (M═Si, Ge, Sn, Pb) Intermetallic Nanoparticles

open access: yesAdvanced Materials, EarlyView.
In situ PXRD data on solvothermal reactions accelerate materials discovery while simultaneously providing fundamental insights into complex crystal formation processes. Using PdxMy (M = Si, Ge, Sn, Pb) as an example, a general formation mechanism is identified, and specific synthesis strategies for ex situ preparation of SnPd2, Sn13Pd20, and SnPd ...
Anders Bæk Borup   +1 more
wiley   +1 more source

Determination of Thirty Trace Elements in Carbonate Rocks by Inductively Coupled Plasma-Mass Spectrometry and Interference Correction

open access: yesYankuang ceshi, 2015
High calcium content in carbonates will result in obvious inhibition or enhancement of element analysis signals when samples are determined by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). In this study, carbonates were openly dissolved by HNO3,
MEN Qian-ni   +5 more
doaj   +1 more source

Trace element analysis of extraterrestrial metal samples by inductively coupled plasma mass spectrometry: the standard solutions and digesting acids

open access: yes, 2016
RATIONALE: Nearly 99% of the total content of extraterrestrial metals is composed of Fe and Ni, but with greatly variable trace element contents. The accuracy obtained in the inductively coupled plasma mass spectrometry (ICP-MS) analysis of solutions of ...
Wang, Guiqin   +5 more
core   +1 more source

Silicon isotope measurement in zircon by laser ablation multiple collector inductively coupled plasma mass spectrometry

open access: yes, 2020
Co-auteur étrangerInternational audienceThis study reports the first Si isotope data measured in zircon using nanosecond laser ablation multiple collector inductively coupled plasma mass spectrometry.
Chaussidon, Marc   +11 more
core   +1 more source

Home - About - Disclaimer - Privacy