Results 61 to 70 of about 491,465 (364)

Level of circulating cytokines and microelements in patients with hemorrhagic fever accompanied by renal syndrome [PDF]

open access: yesСаратовский научно-медицинский журнал, 2011
The research goal is to examine the interrelation of cytokines level (INF-y, TNF-a, IL-2, IL-4, IL-10) and concentration of microelements in blood of patients with hemorrhagic fever accompanied by renal syndrome.
Khasanova G.M.
doaj  

PROBLEMS OF IODIDE IONS DETERMINATION IN MULTIVITAMINS BY INDUCTIVELY COUPLED PLASMA ATOMIC-EMISSION SPECTROMETRY

open access: yesРегуляторные исследования и экспертиза лекарственных средств, 2018
The article looks into the main problems of determination of iodine trace amounts in multivitamins by inductively coupled plasma-atomic emission spectrometry (ICP-AES), i.e. spectral overlaps attributable to macro-components, and the background effect of
V. M. Shchukin   +4 more
doaj   +1 more source

Inductively-Coupled Plasma Mass Spectrometry–Novel Insights From an Old Technology Into Stressed Red Blood Cell Physiology

open access: yesFrontiers in Physiology, 2022
BackgroundIon and metal homeostasis are critical to red blood cell physiology and Inductively Coupled Plasma (ICP) is a decades old approach to pursue elemental analysis.
Daniel Stephenson   +5 more
doaj   +1 more source

Transport and trapping of dust particles in a potential well created by inductively coupled diffused plasma [PDF]

open access: yes, 2016
A versatile linear dusty (complex) plasma device is designed to study the transport and dynamical behavior of dust particles in a large volume. Diffused inductively coupled plasma is generated in the background of argon gas. A novel technique is used to introduce the dust particles in the main plasma by striking a secondary direct current (DC) glow ...
arxiv   +1 more source

Inductively Coupled Plasma Mass Spectrometry [PDF]

open access: yesLaboratory Medicine, 2004
One technique used in clinical laboratories for trace element detection is inductively coupled plasma mass spectrometry, or ICP-MS. Introduced commercially in 1983,1 the basic design is still the same today. It is well-suited to detecting very small amounts of material, in the parts per billion (ppb) to the parts per trillion (ppt) range.2 Samples for ...
openaire   +1 more source

Heavy metals determination in honey samples using inductively coupled plasma-optical emission spectrometry

open access: yesJournal of Environmental Health Science and Engineering, 2015
BackgroundHoney contains a complex mixture of carbohydrates and other minor substances. Elements are minor constituents of honey that may threaten the human health in excess concentrations. So, determining the metals in honey helps its quality control as
Hasan Mohammadi Aghamirlou   +6 more
semanticscholar   +1 more source

Extracorporeal Catalytic Hemoperfusion Therapy for Refractory Septic Shock Using Ceria Nanoparticle‐Embedded Porous Microbeads

open access: yesAdvanced Functional Materials, EarlyView.
This study introduces an extracorporeal hemoperfusion system incorporating porous microbeads embedded with autocatalytic ceria nanoparticles (CeNPs) for targeted reactive oxygen species (ROS) scavenging in septic shock. The blood‐compatible hemoperfusion cartridge demonstrated significant improvements in survival, hemodynamic stability, and organ ...
Pilseon Im   +10 more
wiley   +1 more source

Determination of wholesome elements and heavy metals in safflower (Carthamus tinctorius L.) from Xinjiang and Henan by ICP-MS/ICP-AES

open access: yesJournal of Pharmaceutical Analysis, 2011
An inductively coupled plasma mass spectrometry (ICP-MS) or inductively coupled plasma atomic emission spectrometry (ICP-AES) was developed to determine 19 elements in safflower, a traditional Chinese medicinal herb from Xinjiang Autonomous Region and ...
Ling-Han Jia, Yi Li, Yu-Zhen Li
doaj  

Estudo comparativo de métodos de preparo de amostras de tinta para a determinação de metais e metalóides por técnicas de espectrometria atômica Paint samples preparation methods for metals and methaloids determination by atomic spectrometry techniques

open access: yesQuímica Nova, 2009
This work deals with paint decomposition methods for major, minor and trace elements determination. Three methods were investigated: (1) decomposition in closed quartz vessel and heating in microwave oven; (2) decomposition in open vessel using HNO3 and ...
Fabrina R. S. Bentlin   +2 more
doaj   +1 more source

Influence of Plasma Density Arrangement on Millimeter-Wave Transmission Characteristics [PDF]

open access: yesarXiv, 2023
The advancement of millimeter wave and terahertz technologies have revolutionized high speed wireless networks and precise tracking systems. These technologies offer unique penetration capabilities in specific scenarios, significantly enhancing the capability to investigation plasma. Recent breakthroughs include the precise diagnosis of plasma electron
arxiv  

Home - About - Disclaimer - Privacy