Results 201 to 210 of about 5,416,961 (253)

An Injectable Metal‐Drug Supramolecular Condensate Enables Radiosensitization and Systemic Antitumor Immunity for Post‐Surgical Osteosarcoma Therapy

open access: yesAdvanced Science, EarlyView.
This work designed an injectable metal‐drug supramolecular condensate formed from hafnium ions and alendronate (Hf‐ALN) and loaded with the COX‐2 inhibitor celecoxib (CXB) for synergistic radioimmunotherapy of postoperative osteosarcoma. Mechanistically, upon X‐ray irradiation, Hf enhances radiation energy deposition, ROS generation, and DNA damage ...
Tianhua Xiao   +12 more
wiley   +1 more source

Nanocluster‐Assisted OH Ligand Modification Optimizes Activity and Stability of Fe‐N‐C Catalysts

open access: yesAdvanced Science, EarlyView.
A nanocluster‐assisted ligand engineering stabilizes OH‐modified FeN4 active sites through strong electronic coupling between isolated Fe atoms and adjacent nanoclusters. This synergy optimizes oxygen‐intermediate adsorption, lowers ORR energy barriers, and breaks the conventional activity–stability trade‐off, enabling high ORR activity, exceptional ...
Xue Zhao   +6 more
wiley   +1 more source

Liquid chromatography–inductively coupled plasma mass spectrometry

Journal of Chromatography A, 1999
The technique of coupling liquid chromatography to inductively plasma mass spectrometry (ICP-MS) is reviewed. A brief introduction to the ICP-MS instrument is given as well as methods to couple the two analytical instruments together. The various types of LC that have been used with ICP-MS detection are discussed and advantages over traditional methods
Karen L Sutton, J A Caruso
exaly   +3 more sources

Inductively coupled plasma mass spectrometry‐based immunoassay: A review

open access: yesMass Spectrometry Reviews, 2013
AbstractThe last 10 years witnessed the emerging and growing up of inductively coupled plasma mass spectrometry (ICPMS)‐based immunoassay. Its high sensitivity and multiplex potential have made ICPMS a revolutionary technique for bioanalyte quantification after element‐tagged immunoassay.
Liu, R.   +4 more
openaire   +4 more sources

Applications of inductively coupled plasma mass spectrometry and laser ablation inductively coupled plasma mass spectrometry in materials science

Spectrochimica Acta, Part B: Atomic Spectroscopy, 2002
Abstract Inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) have been applied as the most important inorganic mass spectrometric techniques having multielemental capability for the characterization of solid samples in materials science.
Johanna Sabine Becker
exaly   +2 more sources

Inductively coupled plasma-mass spectrometry

Analytical Proceedings, 1987
The inductively coupled plasma-mass spectrometer combines two analytical facilities to produce an instrument with powerful potential in the field of multi-element trace analysis. The inductively coupled argon plasma is used, not as a source for optical emission measurements (as in ICP-atomic emission spectrometry, Chapter 5), but rather as a source of ...
J. E. Cantle   +3 more
openaire   +2 more sources

Inductively coupled plasma mass spectrometry

SCIENTIA SINICA Chimica, 2014
Fundamental and applied studies on ICP-MS conducted by the scientists in Mainland China in recent 10 years were briefly reviewed. Creative researches on novel sample introduction technique and ICP-MS based bioanalysis have been performed, playing a leading role in respective fields, and those in the fields of elemental speciation and metallomics are ...
NanNan TANG, QiuQuan WANG, LiMin YANG
openaire   +2 more sources

Inductively Coupled Plasma Mass Spectrometry

Analytical Chemistry, 2002
Introduction 4786 Conferences 4788 Book and Reviews 4788 Sample Preparation 4789 Reviews 4789 Original Approaches 4789 Instrument Development, Characterization, and Optimization 4791 Direct Sample Introduction 4791 Nebulization 4791 Plasma Processes 4792 Plasma Sampling Processes 4792 Ion Detection 4792 Spectroscopic Interferences 4793 Nonspectroscopic
openaire   +6 more sources

Inductively coupled plasma mass spectrometry

1989
The first paper describing the coupling of an argon plasma, a highly efficient ion source, and a mass spectrometer was published in 1980 (Houk et al.) as a result of the collaboration between the research group at the Ames Laboratory, Iowa State University (USA) and Gray at the University of Surrey (UK).
Michael Thompson, J. Nicholas Walsh
openaire   +1 more source

Mass spectrometry of inductively coupled plasmas

Analytical Chemistry, 1986
The alliance of the ICP with MS shows promise of extending the sensitivity and selectivity of MS to elemental analysis of solutions. Some additional areas of research interest for ICP-MS include the following: its use as an element and isotope selective detector for chromatography, flow injection analysis, laser ablation, and other sample introduction ...
openaire   +2 more sources

Home - About - Disclaimer - Privacy