Results 261 to 270 of about 3,317,746 (306)
Some of the next articles are maybe not open access.

CT image reconstruction via industrial CT fast scanning

Journal of Instrumentation
Abstract In automated manufacturing and safety inspection, there is a high demand for fast computed tomography (CT) scanning and image reconstruction. Currently, faster scanning can be achieved by reducing the X-ray exposure time within sparse view CT. The faster scanning strategy introduces significant streak artefacts and noise
Lijuan Bai, Yirou Du, Chao Long
openaire   +1 more source

Parametric boundary reconstruction algorithm for industrial CT metrology application

Journal of X-Ray Science and Technology, 2009
High-energy X-ray computed tomography (CT) systems have been recently used to produce high-resolution images in various nondestructive testing and evaluation (NDT/NDE) applications. The accuracy of the dimensional information extracted from CT images is rapidly approaching the accuracy achieved with a coordinate measuring machine (CMM), the ...
Zhye, Yin, Kedar, Khare, Bruno, De Man
openaire   +2 more sources

High-speed CT imaging for today's industry

Insight - Non-Destructive Testing and Condition Monitoring, 2008
Computed Tomography (CT) has been extensively used in industrial inspection, however, production applications have been few, due to the time required for performing CT. This paper describes a high-throughput, production X-ray CT system for inspecting munitions. Various types of defects such as cracks, voids, fuse armed status, and powder fill level are
D Schneberk, N Shashishekhar
openaire   +1 more source

The System of Signal Acquisition and Processing of Industrial CT

2011 International Conference on Control, Automation and Systems Engineering (CASE), 2011
The system of signal acquisition and processing in industrial CT can transfer analog signals outputted by X-ray linear array detector into digital signals and transmit them into computer after uniformity in order to supply data for the image reconstruction of measured object, which plays an important part in CT.
Feng Rong, Changyun Miao, Chenxi Shi
openaire   +1 more source

Perspective on the First 10 Years of the CT Scanner Industry

Academic Radiology, 2003
In the spirit of full disclosure, it should be noted that the author of this article was in charge of GE Medical Systems from 1974 to 1986. During that time, he had no direct contact with GE competitors in the manufacture of computed tomographic (CT) scanners. Twenty years after the introduction of the CT scanner, however, during his retirement, he was
openaire   +2 more sources

The influence of BRDF calibration to CT industry NDT

SPIE Proceedings, 2010
Computed Tomography (CT) testing is an important non-destructive testing technology in industry inspection. So the important work of CT development is the value calibration and the precise result judgment. Bi-directional reflection distribution function(BRDF) as the common spatial characteristic parameter can be fit for the CT data structure in ...
Zilong Liu, Ningfang Liao
openaire   +1 more source

Application of LIBS and CT-TDLAS to Industrial Processes

The International Photonics and Optoelectronics Meeting 2017, 2017
A new collinear long and short DP-LIBS method and CT-TDLAS method were proposed and applied to component measurement and 2D temperature distributions to improve the detection ability and measurement accuracy, which enable real-time measurements in various industrial processes, such as iron and steel making processes, engines, burners and so on.
Yoshihiro Deguchi   +2 more
openaire   +1 more source

Industrial Computed Tomography Technique Development for Industrial Volumetric X-Ray CT

Materials Evaluation, 2022
It is often stated that no two engineers will set up an industrial X-ray computed tomography (CT) scan with the same parameters. In this article, an orderly set of steps is presented that will lead to an acceptable CT scan result for typical cone beam (volumetric) systems with application to denser and/or larger objects.
openaire   +1 more source

Experimental research on rear collimator in γ-ray industrial CT

Applied Radiation and Isotopes, 2009
Rear collimator is one of the key components in the gamma-ray industrial CT, which plays an important role in removing scattering influence and improving the CT spatial resolution. High-performance CT is always associated with a high-quality collimator.
Zhifang, Wu, Jinhui, Liu
openaire   +2 more sources

Interactive Volume Exploration for Feature Detection and Quantification in Industrial CT Data

IEEE Transactions on Visualization and Computer Graphics, 2008
This paper presents a novel method for interactive exploration of industrial CT volumes such as cast metal parts, with the goal of interactively detecting, classifying, and quantifying features using a visualization-driven approach. The standard approach for defect detection builds on region growing, which requires manually tuning parameters such as ...
Markus Hadwiger   +5 more
openaire   +3 more sources

Home - About - Disclaimer - Privacy