Abstract A core drilled through shocked and faulted Archean granitoid gneisses and dolerites in the eroded peak ring of the 70–80 km diameter Morokweng impact structure intersects multiple centimeter‐ to meter‐wide clastic‐matrix breccias containing a polymict clast population of lithic and mineral clasts and altered, millimeter‐ to centimeter ‐size ...
Roger L. Gibson +3 more
wiley +1 more source
A G-Code-Driven Modeling and Thermo-Mechanical Coupling Analysis Method for the FDM Process of Complex Lightweight Structures. [PDF]
Li D, Dun Y, Yang Z, Zhou R, Chen Y.
europepmc +1 more source
Microbial mats in dinosaur ichnocoenoses
ABSTRACT Until now, the significance of microbial mats in preservation of dinosaur tracks and in reconstructing the palaeoenvironment in which dinosaurs roamed was rarely studied. Dinosaur tracks are commonly found close to ancient aquatic bodies where moist sediment had once allowed footstep registration.
Nora Noffke +3 more
wiley +1 more source
A Comprehensive Investigation of Infill Geometry Effects on the Mechanical Performance of Polymer 3D Printed Components. [PDF]
Alzahrani FJ +3 more
europepmc +1 more source
ABSTRACT This research examines the spatial and geochemical interactions between mat‐forming microorganisms and thalassinid shrimp in an intertidal flat situated on the shores of Willapa Bay, Washington, USA. The study serves as a contemporary analog for the relationships between mats and burrowing organisms in deep time.
Brette S. Harris +9 more
wiley +1 more source
Parameter Optimization of Biodegradable Composite PLA-Wood with New-Generation Infill Pattern. [PDF]
Turan MK +3 more
europepmc +1 more source
The Seismic Expression of Core Complex‐Style Extensional Detachment Faults in Rifted Margins
ABSTRACT The identification of core complex‐style extensional detachment faults (CCDFs) in rifted margins is crucial for accurately restoring their stratigraphic and thermal histories. Yet recognising CCDFs in seismic reflection images is challenging due to their faint topographic expression; the lack of associated abrupt offset in seismic reflections;
Pauline Chenin +3 more
wiley +1 more source
Reconstruction of an orbital fracture in a mare using a 3D‐printed patient‐specific implant
Abstract Objective To describe surgical repair of an orbital wall fracture communicating with the caudal maxillary sinus using a three dimensional (3D)‐printed, patient‐specific implant (PSI). Study design Case report. Animal A 25‐year‐old Haflinger mare (370 kg). Methods The mare presented with severe chemosis and emphysema of the left upper and lower
Jennifer Gernhardt +5 more
wiley +1 more source
Assessment of Seismic Performance and Structural Health Monitoring of a Retrofitted Reinforced Concrete Structure with Polyurethane-Based Interventions and Vertical Greenery Systems. [PDF]
Rousakis T +13 more
europepmc +1 more source

