Results 11 to 20 of about 11,092 (338)

A laboratory evaluation of nozzle tip damage in four generations of intraocular lens injector systems using a self-developed damage scale

open access: yesScientific Reports, 2022
During intraocular lens (IOL) implantation it is not uncommon for the injector’s nozzle-tip to get damaged. However, the damage has not been systematically described or evaluated using an objective scale.
Hui Fang   +6 more
doaj   +1 more source

Nozzle tip damage in three generations of intraocular lens injector models: an experimental laboratory study

open access: yesBMC Ophthalmology, 2023
Purpose To assess the nozzle tip damage of IOL injectors in three generations from the same manufacturer using the self-developed system—the Heidelberg Score for IOL Injector Damage.
Lu Zhang   +3 more
doaj   +1 more source

Results of Implantation of a New Hydrophobic Acrylic Monofocal Intraocular Lens in a Preloaded Injector

open access: yesOftalʹmologiâ, 2023
Purpose. To evaluate clinical and functional results of implantation of a new hydrophobic acrylic monofocal IOL in a preloaded injector.Methods. The prospective study included 60 patients (66 eyes) after Hoya iSert® 250/251 IOL implantation (31 patients,
K. B. Pershin   +3 more
doaj   +1 more source

Cataract Surgery Results of New Lens Implantation “Synthesis”

open access: yesOftalʹmologiâ, 2023
Purpose. Analysis of the cataract surgery visual outcomes and advantages of intraocular lens Synthesis SIPY.Material and methods. We have operated 43 eyes with cataract (38 patients) using Synthesis SIPY lens. Non-corrected visual acuity was 0.13 ± 0.08,
E. A. Ivachev   +3 more
doaj   +1 more source

Simple technique to avoid inadvertent upside-down implantation of multipiece IOL with injector [PDF]

open access: yesBMJ Case Reports, 2021
The evolution of multipiece intraocular lenses (IOLs) has provided the option of sulcus implantation in situations wherein the bag implantation is not feasible. Multipiece IOLs are implanted in eyes with an intact anterior capsular rim and posterior capsular tear or with pre-existing ...
Sudarshan Khokhar   +3 more
openaire   +2 more sources

Comparative evaluation of an automated preloaded delivery system with a non-preloaded system

open access: yesIndian Journal of Ophthalmology, 2022
Purpose: To evaluate a single surgeon's experience with an automated preloaded intraocular lens (IOL) delivery system and a nonpreloaded system. Methods: This was a prospective, observational case series.
Rajesh S Joshi
doaj   +1 more source

A nonvolatile analog programmable voltage source using the VIPMOS EEPROM structure [PDF]

open access: yes, 1993
A programmable voltage source using the vertical injection punchthrough based MOS (VIPMOS) EEPROM structure is presented. The circuit operates at a single 5-V supply and the output voltage is continuously available even during programming.
Hoen, Klaas   +4 more
core   +2 more sources

On the robustness of ultra-high voltage 4H-SiC IGBTs with an optimized retrograde p-well [PDF]

open access: yes, 2019
The robustness of ultra-high voltage (>10kV) SiC IGBTs comprising of an optimized retrograde p-well is investigated. Under extensive TCAD simulations, we show that in addition to offering a robust control on threshold voltage and eliminating punch ...
Antoniou, M.   +5 more
core   +1 more source

Hypothalamic excitatory amino acid receptors mediate stress-induced tachycardia in rats [PDF]

open access: yes, 1992
The role of hypothalamic excitatory amino acid (EAA) receptors in mediating the cardiovascular response to stress was examined using conscious chronically instrumented rats.
DiMicco, Joseph A., Soltis, Robert P.
core   +2 more sources

Thalamic inputs to dorsomedial striatum are involved in inhibitory control: evidence from the five-choice serial reaction time task in rats [PDF]

open access: yes, 2017
Rationale Corticostriatal circuits are widely implicated in the top-down control of attention including inhibitory control and behavioural flexibility. However, recent neurophysiological evidence also suggests a role for thalamic inputs to striatum in
A Bari   +36 more
core   +2 more sources

Home - About - Disclaimer - Privacy