Controlling Inrush Currents in Inductively Coupled Power Systems
International Journal of Emerging Electric Power Systems, 2005In an Inductively Coupled Power Transfer (ICPT) system, a multiplicity of (moving) loads take power from an elongated conductive loop (track) excited by a current in the range of 15-125A by magnetic induction at a VLF frequency of between 5-50kHz.
J.T. Boys, C.I. Chen, G.A. Covic
openaire +1 more source
IEEE Transactions on Power Delivery, 2020
Switching-on a power transformer creates energizing inrush current (EIC) which in turn leads to sympathetic inrush current (SIC) in adjacent in-service transformers (ITs).
Arash Moradi, S. M. Madani
semanticscholar +1 more source
Switching-on a power transformer creates energizing inrush current (EIC) which in turn leads to sympathetic inrush current (SIC) in adjacent in-service transformers (ITs).
Arash Moradi, S. M. Madani
semanticscholar +1 more source
Capacitive current switching of Vacuum Interrupters and inrush currents
2012 25th International Symposium on Discharges and Electrical Insulation in Vacuum (ISDEIV), 2012Capacitive current switching has become increasingly necessary for power factor correction in distribution systems. However, Restrikes are potentially dangerous as they could cause overvoltage which can be harmful to the power system. The dielectric strength of the Vacuum Interrupter (VI) in a capacitive current switching is strongly determined by a ...
He Yang, Yingsan Geng, Zhiyuan Liu
openaire +1 more source
The Inrush Current Eliminator of Transformer
2012In the power industry, transformers are key components for electrical energy transfer. However, the transformer always is affected by inrush current problems of itself. The inrush currents will cause power system network with voltage dip, harmonic, over-voltage, sympathetic current and mal-trip of protective relay and so on.
Li-Cheng Wu, Chih-Wen Liu
openaire +1 more source
Current transformer performance for inrush current in power transformers
Electric Power Systems Research, 1988Abstract A mathematical model has been developed for a current transformer to predict the transient performance during switch-in of a power transformer with residual flux. Typical 50 - 100 - 200/1 and 300/1 current transformers have been simulated and the secondary current response has been computed for different values of the current transformer ...
B.T. Desai, H.O. Gupta, M.K. Vasantha
openaire +1 more source
Research on Magnetizing Inrush Current and Fault Identification of Transformer Based on VMD-SVM
2020 IEEE International Conference on Information Technology,Big Data and Artificial Intelligence (ICIBA), 2020Aiming at the problem of misoperation of transformer differential protection that is susceptible to inrush current in the past, this paper proposes an identification method of excitation inrush current based on variational mode decomposition-support ...
Jing Meng, Jingyi Du
semanticscholar +1 more source
2016 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC), 2016
Magnetizing inrush current will occur when the transformer is energized without load, which will cause that the already energized neighboring transformers generate sympathetic inrush current. The currents have influence on the operation of HVDC system if they occur in the converter transformers due to their characteristics.
null Rui Li +6 more
openaire +1 more source
Magnetizing inrush current will occur when the transformer is energized without load, which will cause that the already energized neighboring transformers generate sympathetic inrush current. The currents have influence on the operation of HVDC system if they occur in the converter transformers due to their characteristics.
null Rui Li +6 more
openaire +1 more source
, 2020
This study proposes a time-domain analytical-numerical method in order to precisely assess the three-phase three-limb core-type transformer inrush current considering the nonlinear behavior of the iron core.
Z. Taghikhani +2 more
semanticscholar +1 more source
This study proposes a time-domain analytical-numerical method in order to precisely assess the three-phase three-limb core-type transformer inrush current considering the nonlinear behavior of the iron core.
Z. Taghikhani +2 more
semanticscholar +1 more source
A Non-Control Transformer Inrush Current Limiter
2006 IEEE International Conference on Industrial Technology, 2006A new method is proposed for inrush current reduction of under load transformers. The proposed limiter consists of a control-less diode-bridge and a single coil that connects in series with each-phase of transformer. It is necessary using three similar circuits for three-phase transformers.
M. Abapour, M. Tarafdar haqh
openaire +1 more source
Characteristic analysis of zero-mode inrush current of high-impedance transformer
, 2020In recent years, zero-sequence overcurrent protection misoperated frequently when the high-impedance transformers are energized without load. This paper studies the characteristics of zero-mode inrush current of the high-impedance transformers, including
Wenbin Cao +5 more