Oblique Cutting Based Mechanical Model for Insertion Torque of Dental Implant
The insertion torque of a dental implant is an important indicator for the primary stability of dental implants. Thus, the preoperative prediction for the insertion torque is crucial to improve the success rate of implantation surgery.
Luli Li +4 more
doaj +1 more source
Insertion torque and resonance Frequency analysis (ISQ) as predictor methods of implant osseointegration [PDF]
Aim Determining appropriate primary stability at time of implant placement is a key therapeutic decision. The aim of the study was to compare insertion torque and implant stability quotient (ISQ) obtained at the time of implant placement, as predictors ...
Utsman R. +5 more
core +2 more sources
Relation Between Insertion Torque and Implant Stability Quotient: A Clinical Study. [PDF]
Objectives This study aimed to assess the relation between the insertion torque and implant stability quotient (ISQ recorded immediately and 6 months after implant placement).
do Vale Souza JP +8 more
europepmc +2 more sources
High insertion torque versus regular insertion torque: early crestal bone changes on dental implants in relation to primary stability-a retrospective clinical study. [PDF]
<jats:title>Abstract</jats:title><jats:p>The aim of the presented retrospective study was to evaluate the early crestal bone changes around an implant type designed for high primary stability.
Ruppin JM, Stimmelmayr M.
europepmc +2 more sources
Introduction: The achievement of good osseointegration in immediate implant placement can occur in the presence adequate primary stability. The insertion torque varies between cases depending on many factors.
Elian Samy, Salem Ahmed
doaj +1 more source
Mandibular bone characteristics, drilling protocols, and final insertion torque for titanium-zirconium mini-implants for overdentures: a cross-sectional analysis [PDF]
ObjectiveThe aim of this study was to assess the final insertion torque values achieved using site-specific drilling protocols for a novel mini implant system for removable complete overdentures.
Leles, José Luiz Rodrigues +21 more
core +2 more sources
Laparoscopic procedures have become indispensable in gastrointestinal surgery. As a minimally invasive process, it begins with primary trocar insertion. However, this step poses the threat of injuries to the gastrointestinal tract and blood vessels.
Nantida Nillahoot +4 more
doaj +1 more source
Influence of cortical thickness on the stability of mini-implants with microthreads
The objective of this study was to assess the influence of cortical thickness and bone density on the insertion torque of a mini-implant (MI) with microthreads. Mini-implants with lengths of 6 and 8 mm in the active part were inserted into synthetic bone
Giselle Naback Lemes VILANI +4 more
doaj +1 more source
A study on the use of the Osstell apparatus to evaluate pedicle screw stability: An in-vitro study using micro-CT. [PDF]
Pull-out force and insertion torque have not been generally used as intraoperative measures for the evaluation of pedicle screw stability because of their invasiveness.
Daisuke Nakashima +4 more
doaj +1 more source
Torque Requirements and the Influence of Pilot Holes on Orthodontic Miniscrew Microdamage
This study aimed to quantify the microdamage to cortical bone of different thickness and the maximum insertion torque during orthodontic miniscrew implant (OMI) placement with and without a pilot hole. Forty-five porcine bone specimens were prepared with
Sven W. Jensen +3 more
doaj +1 more source