Results 161 to 170 of about 406 (203)
Some of the next articles are maybe not open access.
Design and Installation of Zero-Tension Lysimeters in an Inclined Cover
Unsaturated Soils 2006, 2006The infiltration component of the water budget in a soil cover layer is difficult to measure under field conditions. Often, zero-tension (or pan) lysimeters are used for that purpose. Although they are relatively cheap and easy to build, as well as easy to install, their design may be more complex than one thinks.
Fatima Marinho
exaly +2 more sources
2012 IEEE International Energy Conference and Exhibition (ENERGYCON), 2012
The outdoor testing is useful for the qualification and acceptation of high temperature low sag (HTLS) conductors. The paper describes a pilot installation for the monitoring of a conductor in an operating line. The monitoring system measures the conductor tension, the conductor temperature and weather magnitudes. This system includes a methodology for
Elvira Fernández +2 more
exaly +2 more sources
The outdoor testing is useful for the qualification and acceptation of high temperature low sag (HTLS) conductors. The paper describes a pilot installation for the monitoring of a conductor in an operating line. The monitoring system measures the conductor tension, the conductor temperature and weather magnitudes. This system includes a methodology for
Elvira Fernández +2 more
exaly +2 more sources
Method and installation for determining moduli of elasticity of materials in static tension
Strength of Materials, 1987A F Voitenko +2 more
exaly +2 more sources
An installation to subject materials to tension at high strain rates
Soviet Applied Mechanics, 1969Stepanov G V
exaly +2 more sources
Tension Control Bolts: Strength and Installation
Journal of Bridge Engineering, 1998Tension control bolts are a type of alternative design fastener, permitted by the Research Council on Structural Connections. The bolt has a splined end that extends beyond the threaded portion of the bolt and an annular groove between the threaded portion of the bolt and the splined end.
Geoffrey L. Kulak, Scott T. Undershute
openaire +1 more source
Lagen Bridge Cables Installation and Tensioning
IABSE Congress Reports, 2016<p>The Lagen Bridge is the first application of prefabricated HDPE sheathed full locked coil cable stays on a Norwegian bridge. The structure is located in Kvam, about 100 km North from Lillehammer, and it is part of the development project of route E6 between Biri and Otta.
Silvia Geyer +2 more
openaire +1 more source
4938632 Tension leg platform and method for installation of the same
Deep Sea Research Part B Oceanographic Literature Review, 1991exaly +2 more sources
Design and Installation of a Tension Moored Wind Turbine
Volume 5: Ocean Space Utilization; Polar and Arctic Sciences and Technology; The Robert Dean Symposium on Coastal and Ocean Engineering; Special Symposium on Offshore Renewable Energy, 2007This paper describes the design of the floater and the mooring system for a small wind turbine. The engineering basis and the hydrodynamics calculations are described, as well as the installation and commissioning sequences.
Thomas Zambrano +3 more
openaire +1 more source
Critical Aspects to the Design and Installation of Top Tensioned Risers
Volume 3: Pipeline and Riser Technology; CFD and VIV, 2007Dual and single casing top tensioned risers are widely used by operators for deepwater floating production facility developments. These riser types provide direct vertical access for completions and workover. These single and dual barrier risers are a stable riser concept utilizing the effective tension distribution between casings and tubing to ...
Andy Westlake, Ronan Quinn
openaire +1 more source
Parafoudres basse tension - Description. Installation
Réseaux électriques et applications, 2003Cet article presente les criteres de choix et les regles d'installation des parafoudres basse tension. Il doit etre lu en conjonction avec la premiere partie qui traite des composants de parafoudres et des reseaux. Il faut prendre en compte les fonctions secondaires, telles que l'indicateur de defaut ou le renvoi d’etat a distance, mais il ne faut pas ...
openaire +1 more source