Results 171 to 180 of about 103,546 (243)
This work presents self‐propelled CRISPR/Cas9‐functionalized Au–MRs for rapid, amplification‐free, “on‐the‐fly” DNA detection. By harnessing motion‐assisted signal recovery, the platform achieved the limit of detection in low fM DNA concentrations, enabling detection across a wide dynamic range within only 5 min, which is significantly faster than any ...
Jyoti +3 more
wiley +1 more source
Experimental dataset of charge and discharge patterns in a 1200Ah OpzS battery bank. [PDF]
Rocha J, Aguasca R, Méndez M.
europepmc +1 more source
Fast‐Responding O2 Gas Sensor Based on Luminescent Europium Metal‐Organic Frameworks (MOF‐76)
Luminescent MOF‐76 materials based on Eu(III) and mixed Eu(III)/Y(III) show rapid and reversible changes in emission intensity in response to O2 with very short response times. The effect is based on triplet quenching of the linker ligands that act as photosensitizers. Average emission lifetimes of a few milliseconds turn out to be mostly unaffected by
Zhenyu Zhao +5 more
wiley +1 more source
Advances in Neuromodulation and Digital Brain-Spinal Cord Interfaces for Spinal Cord Injury. [PDF]
Jaszczuk P +6 more
europepmc +1 more source
Glyphosate (GLY) and its primary metabolite, aminomethylphosphonic acid (AMPA), are photodegraded using a poly(vinylidene fluoride) membrane with immobilized titanium dioxide (PVDF‐TiO2) in a continuous flow‐through operation under solar light. At optimized conditions, the PVDF‐TiO2 membrane achieved 95% GLY and 80% AMPA removal with •O2− as the ...
Phuong B. Trinh +4 more
wiley +1 more source
This study presents the BioCLEAR system, a highly transparent and conductive neural electrode array composed of silver nanowires (AgNWs) and doped PEDOT:PSS, enabling neural recordings with minimal optical artifacts. When integrated with a GRIN lens, this cost‐effective neural implant allows simultaneous electrophysiological recording and GCaMP6‐based ...
Dongjun Han +17 more
wiley +1 more source
Atrioventricular Synchrony Algorithm Modeling of a Leadless Pacemaker Family: A Virtual Patient Analysis. [PDF]
Leal MA +6 more
europepmc +1 more source
Ionic Control of Microstructure and Lubrication in Charged, Physically Cross‐Linked Hydrogels
Here, charged, physically cross‐linked poly(methacrylamide‐co‐methacrylic acid) hydrogels stabilized by a short‐range attractive, long‐range repulsive potential is investigated. This work uncovers how salt addition alters not only swelling, but also the microstructure and dynamics, near‐surface stiffness and charge, and ultimately, its lubricity. Salts
Alexander Deptula +1 more
wiley +1 more source
Decoding the Solution for Man-at-the-End Attacks and Reverse Engineering on IoMT Devices: An Experimental Review of Techniques and Defences. [PDF]
T AH, Sriraman H.
europepmc +1 more source
A scalable one‐step copolymerization strategy is developed to produce low‐cost microporous ion exchange membranes that boost both the efficiency and lifespan of flow batteries. When combined with organic electrolytes in aqueous systems, these membranes enable safe and cheap flow battery energy storage, supporting the widespread integration of renewable
Jiaye Liu +7 more
wiley +1 more source

