Results 51 to 60 of about 14,778 (170)
Avoiding financial losses requires preventing catastrophic oil‐filled power transformer breakdowns. Continuous online transformer monitoring is needed.
Md. Manzar Nezami +6 more
doaj +1 more source
Aging monitoring of electrical machines using winding high frequency equivalent circuits
This study defines a monitoring method based on impedance analysis in the upper part of the spectrum. It focuses on the analysis of the high frequency behavior of electrical machines windings considering the turn-to-turn capacitance variations (delta-C ...
Ait-Amar Sonia +2 more
doaj +1 more source
The existence of a ring network significantly increases the proportion of harmonic components in the DC system branch current, correspondingly diminishing the low-frequency components, resulting in a decrease in signal-to-noise ratio and negatively ...
Xiang Li +4 more
doaj +1 more source
This paper presents an analysis of the aging of oil-paper insulation using partial discharge (PD) patterns and clustering methods. The four-quadrant model of partial discharge patterns is employed.
Ming-Shou Su +4 more
doaj +1 more source
The status of an optic–electric composite high-voltage submarine cable (referred to as submarine cable) can be monitored based on optical fiber-distributed sensing technology, and at the same time, no additional sensor is needed in the monitoring system.
Chao Luo +7 more
doaj +1 more source
Inverter-fed machines are widely used in electric vehicle drive systems and have shown a trend toward high voltage and frequency in recent years. They are subjected to multiple types of stress during operation, causing potential short-circuit fault ...
Zihan Zou, Senyi Liu, Jinsong Kang
doaj +1 more source
Accurate assessment of high-voltage cable insulation condition is essential for safe operation in complex tunnel environments. Traditional methods relying on single diagnostic indicators and fixed weighting schemes often suffer from limited accuracy and ...
Qianqiu Shao +6 more
doaj +1 more source
Insulation Online Monitoring Method for Dry-Type Current Transformers Based on Virtual Voltage
To improve the accuracy of insulation state online monitoring for capacitive dry-type current transformers (CTs) and to address the limitations of traditional methods relying on potential transformer (PT) voltage signals and reference devices, a virtual ...
Junjie Zhang +6 more
doaj +1 more source
Improved Condition Monitoring of Composite Insulators
Although the cost of investment in power lines insulators is 3 - 5% of the total cost of the installation, the impact of their performance on reliability, failure costs, maintenance routines, etc in power systems is tens of times higher. Composite insulators were introduced 50 years ago and have been used around the world with consistently good ...
openaire +1 more source

