Insulator detection in transmission line based on Log AdaBoost [PDF]
Insulator detection is an important task for safe and reliable operation of smart grid. Due to various background interferences in insulator images, most traditional image processing methods cannot achieve good performance.
Meijin Lin, Hao Chen, Haoyuan Luo
doaj +2 more sources
Impact of increased temperature of lower end-fitting of a composite long rod insulator on its mechanical strength under variable loads [PDF]
This paper describes results of tensile mechanical strength testing of two types of composite suspension line insulators from two manufacturers. In order to take into account the operation of composite insulators in overhead transmission lines with high ...
Jerzy Bielecki +2 more
doaj +1 more source
In order to study the influence of tension insulator string’s weight on the sags and tensions of ultra-high voltage (UHV) conductors, full-scale testing and theoretical analysis are carried out. The full-scale testing of sags of a three-span transmission
Gang SONG +3 more
doaj +1 more source
Durability forecast of long rod composite insulators operating under variable mechanical loading conditions [PDF]
Suspension line insulators are during their operation subject to static forces and variable loads, usually of a cyclic character. These variable loads have a significant impact on the mechanical durability of composite insulators.
Jerzy Bielecki, Jacek Wańkowicz
doaj +1 more source
Analysis of partial discharges in supporting insulators [PDF]
The diagnostics of overhead power lines is an important issue in the modern electric power industry. Sometimes supporting insulators are destroyed by external factors.
D. A. Polyakov +4 more
doaj +1 more source
Research on Zero Value Detection Technology of Porcelain Insulator [PDF]
High-voltage insulators are one of the devices widely used in power systems, and their pros and cons are directly related to the safe and stable operation of the power system.
Mao Xiaopo +9 more
doaj +1 more source
With the increase in the voltage and capacitance of gas-insulated transmission lines (GILs), the insulation failure of GIL has attracted more and more attention.
Li Xing +5 more
doaj +1 more source
Outdoor insulators may experience stress due to severe environmental conditions, such as pollution and contamination. Through the identification of partial discharges by ultrasonic noise, it is possible to assess the possibility of a power grid failure ...
Stefano Frizzo Stefenon +5 more
doaj +1 more source
Surface tracking and erosion is an irreversible degradation occurring on the insulator surface, and this can ultimately lead to failure of the insulator.
Adnan Krzma +2 more
doaj +1 more source
Interfacial bonding enhancement of the RTV recoating with sandwiched contaminant by plasma jet
Room temperature vulcanised (RTV) silicone rubber is widely used in electrical power system, applied to the glass or porcelain insulator surface to enhance insulation.
Shanshan Wang +6 more
doaj +1 more source