Results 11 to 20 of about 63,572 (304)

Monitoring insulator contamination level under dry condition with a microwave reflectometer [PDF]

open access: yes, 2015
—Build-up of surface contamination on high voltage insulators can lead to an increase in leakage current and partial discharge, which may eventually develop into flashover. Conventional contamination level monitoring systems based on leakage current,
Jiang, Yan   +5 more
core   +1 more source

Pengaruh Variasi Insulator Saluran Chilled Water Terhadap Performansi Prototype Mini Water Chiller

open access: yesQuantum Teknika, 2021
The high heat transfer rate from the environment to the chilled water pipe will affect the performance of the mini water chiller prototype, so it is necessary to insulate the chilled water pipe using the right insulator to optimize the performance of the
Buddhi Satya Utama   +2 more
doaj   +1 more source

Detection Method for Damaged Rotating Insulator Based on Adaptive Key Points [PDF]

open access: yesJisuanji gongcheng, 2023
Aiming at the problems of missing detection and inaccurate positioning caused by uncertain insulator direction, complex background, and occlusion in transmission line detection images, this study proposes a detection method for damaged rotating insulator
Yujiang LONG, Wei WEI, Yu SHU, Zhenggang ZHANG, Daolei WANG, Feng LI
doaj   +1 more source

Classification of common discharges in outdoor insulation using acoustic signals and artificial neural network

open access: yesHigh Voltage, 2019
Condition monitoring of outdoor insulation systems is crucial to the integrity of distribution and transmission overhead lines and substations. The objective of this study is to use a commercial acoustic sensor along with artificial neural network (ANN),
Satish Polisetty   +4 more
doaj   +1 more source

Fatigue Damage Analysis of Composite Insulator Cor Rod/sheath Interface [PDF]

open access: yesMATEC Web of Conferences, 2019
A self-made fatigue testing machine was used to simulate the damage process of the insulator interface under working conditions and the damage degree is evaluated by the compressive shear test. The improved interface adhesion model reflects the interface
Zhao Xinze   +5 more
doaj   +1 more source

Study on pollution flashover characteristic of insulators on 500 kV AC transmission lines in high-altitude area

open access: yesThe Journal of Engineering, 2019
Pollution flashover performance of insulators is one of the key factors to be considered in the selection of external insulation for transmission lines at high-altitude areas.
Ruiping Huang, Jun Zhou, Yueneng Xu
doaj   +1 more source

Mining the Utricularia gibba genome for insulator-like elements for genetic engineering

open access: yesFrontiers in Plant Science, 2023
IntroductionGene expression is often controlled via cis-regulatory elements (CREs) that modulate the production of transcripts. For multi-gene genetic engineering and synthetic biology, precise control of transcription is crucial, both to insulate the ...
Daniel Laspisa   +8 more
doaj   +1 more source

Influence of pollution chemical components on AC flashover performance of various types of insulators

open access: yesHigh Voltage, 2019
The pollution on insulators is composed of various chemical components, which threaten the stability of external insulation. However, the existing insulation designs have not taken this issue into consideration.
Zhongyi Yang   +5 more
doaj   +1 more source

Monitoring contamination level on insulator materials under dry condition with a microwave reflectometer [PDF]

open access: yes, 2016
Current techniques used for monitoring the levels of contamination on high voltage insulators, such as leakage current and infrared, are not effective in dry conditions since they require the surface of the insulator to be wetted by fog, rain or snow. If
Jiang, Y.   +5 more
core   +1 more source

High voltage outdoor insulator surface condition evaluation using aerial insulator images

open access: yesHigh Voltage, 2019
High voltage insulator detection and monitoring via drone-based aerial images is a cost-effective alternative in extreme winter conditions and complex terrains.
Damira Pernebayeva   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy