Results 1 to 10 of about 140,581 (165)
Wide-Viewing-Angle Integral Imaging System with Full-Effective-Pixels Elemental Image Array [PDF]
There exists a defect of the narrow viewing angle in the conventional integral imaging system. One reason for this is that only partial pixels of each elemental image contribute to the viewing angle and the others cause image flips. In this paper, a wide-
Zesheng Liu, Dahai Li, Huan Deng
doaj +2 more sources
Computational Integral Imaging Reconstruction via Elemental Image Blending without Normalization [PDF]
This paper presents a novel computational integral imaging reconstruction (CIIR) method using elemental image blending to eliminate the normalization process in CIIR. Normalization is commonly used in CIIR to address uneven overlapping artifacts.
Eunsu Lee, Hyunji Cho, Hoon Yoo
doaj +2 more sources
High-Aperture-Ratio Dual-View Integral Imaging Display [PDF]
Low aperture ratio is a problem in the conventional dual-view integral imaging (DVII) display using a point light source array. A high-aperture-ratio DVII display using a gradient width point light source array is reported in this work.
Bai-Chuan Zhao, Fan Yang, Fei Wu
doaj +2 more sources
Three-Dimensional Integral Imaging with Enhanced Lateral and Longitudinal Resolutions Using Multiple Pickup Positions [PDF]
In this paper, we propose an enhancement of three-dimensional (3D) image visualization techniques by using different pickup plane reconstructions. In conventional 3D visualization techniques, synthetic aperture integral imaging (SAII) and volumetric ...
Jiheon Lee, Myungjin Cho
doaj +2 more sources
Integral Imaging Display System Based on Human Visual Distance Perception Model [PDF]
In an integral imaging (II) display system, the self-adjustment ability of the human eye can result in blurry observations when viewing 3D targets outside the focal plane within a specific range.
Lijin Deng +3 more
doaj +2 more sources
Introduction: The usefulness of contrast enhanced mammography (CEM) for assessing architectural distortion (AD) has not been defined. This study aimed to determine the diagnostic accuracy of AD enhancement on CEM for predicting malignancy and its ...
Claudia B. Corona-Gonzalez +3 more
doaj +1 more source
The smart pseudoscopic-to-orthoscopic conversion (SPOC) algorithm can synthesize a new elemental image array (EIA) using the already captured EIA, but the algorithm only relies on one simulated ray to establish the mapping relationship between the ...
Yan Mao +5 more
doaj +1 more source
Tabletop autostereoscopic displays have the advantage of displaying realistic three-dimensional (3D) content. In particular, the Integral imaging (InIm) method is superior in tabletop displays, as it is possible to make the system small using microlens ...
Daerak Heo +5 more
doaj +1 more source
Aerial Projection 3D Display Based on Integral Imaging
We proposed an aerial projection 3D display based on integral imaging. It is composed of a projector, a lens-array holographic optical element (HOE), and two parabolic mirrors.
Wu-Xiang Zhao +4 more
doaj +1 more source
The representation of three-dimensional volumetric pixels, voxels, is an important issue for the near-to-eye displays (NEDs) to solve the vergence-accommodation conflict problem. Although the holographic waveguides using holographic optical element (HOE)
Jiwoon Yeom, Yeseul Son, Kwangsoon Choi
doaj +1 more source

