Results 171 to 180 of about 2,957,238 (360)
Multi‐institutional study on image quality for a novel CBCT solution on O‐ring linac
Abstract Introduction This work presents a multi‐institutional study on image quality provided by a novel cone beam computed tomography (CBCT). The main goal is to investigate the consistency of imaging performance across multiple institutions.
Luis Agulles‐Pedrós+11 more
wiley +1 more source
Abstract This study aimed to evaluate the dose‐exposure reduction effect of a crystalline lens with a bismuth eye shield using cone‐beam computed tomography (CBCT) for head image‐guided radiation therapy. The ocular surface dose of the head phantom (THRA‐1) is defined as a crystalline lens exposure dose and is measured using a radiophotoluminescence ...
Tatsuya Yoshida+5 more
wiley +1 more source
Measurement of CT radiation beam width with a pencil ionization chamber and radiopaque mask
Abstract Purpose This study compares fan beam CT scanner radiation beam widths measured with a pencil ionization chamber‐radiopaque mask technique with commonly used film and computed radiography (CR) measurements. Methods For a given fan beam CT scanner x‐ray beam, the ionization chamber‐mask technique determines the radiation beam width by exposing a
Rani Al‐Senan+2 more
wiley +1 more source
Abstract Background The dose‐averaged linear energy transfer (LETD) in proton therapy (PT) has in pre‐clinical studies been linked to the relative biological effectiveness (RBE) of protons. Until recently, the most common PT delivery method in prostate cancer has been double‐scattered PT, with LETD only available through dedicated Monte Carlo (MC ...
Rasmus Klitgaard+7 more
wiley +1 more source
Electrochemical protein biosensors for disease marker detection: progress and opportunities
The development of artificial intelligence-enabled medical health care has created both opportunities and challenges for next-generation biosensor technology. Proteins are extensively used as biological macromolecular markers in disease diagnosis and the
Lanpeng Guo+7 more
doaj +1 more source
Critical nonreciprocity in gyrotropic coupled-waveguide system for TE-mode optical isolator and circulator [PDF]
Photonic integrated circuits (PICs) increasingly require more advanced integrated functionalities and devices to meet the key application challenges. This evolution with the serial integration of optical functions in the same photonic circuit often results in internal reflections and optical feedback, which can specifically destabilize lasers.
arxiv
New reactive polymeric systems for use as waveguide materials in integrated optics [PDF]
Christian Dreyer+7 more
openalex +1 more source
A review of artificial intelligence in brachytherapy
Abstract Artificial intelligence (AI) has the potential to revolutionize brachytherapy's clinical workflow. This review comprehensively examines the application of AI, focusing on machine learning and deep learning, in various aspects of brachytherapy.
Jingchu Chen+4 more
wiley +1 more source
Design of an Integrated Optics Sensor Structure Based on Diamond Waveguide for Hemoglobin Property Detection. [PDF]
Struk P.
europepmc +1 more source