Results 191 to 200 of about 6,729 (231)
Some of the next articles are maybe not open access.
3D interdigitated electrode array in the microchannel free of reference and counter electrodes
Biosensors and Bioelectronics, 2018We demonstrate the three-dimensional (3D) interdigitated array (IDA) chip that operates without reference and counter electrodes, which are necessary components to apply enough potential to trigger the intended redox process, but used unwieldy for chip-based electrochemical detection.
Dahye, Lee +5 more
openaire +2 more sources
Fabrication of Interdigital Electrodes for Monolithic Biosensing
2021Interdigital electrodes/contacts (IDCs) based sensors are widely used in a variety of chemical and biological sensors, which presents promising advantages such as high sensitivity, low electron mobility, enhanced gate conductivity and increased signal to noise ratio.
Nireekshan Kumar Sodavaram +1 more
openaire +1 more source
A Micromachined Electrochemical Angular Accelerometer Based on Interdigital Electrodes
2021 IEEE 16th International Conference on Nano/Micro Engineered and Molecular Systems (NEMS), 2021This study proposes a micromachined electrochemical angular accelerometer based on interdigital electrodes, with the ability to measure low-frequency angular acceleration. In this paper, the design, fabrication, and characterization of the angular accelerometer were included, with a sensitivity of 100 V/(rad/s2) at 0.01Hz.
Tian Liang +10 more
openaire +1 more source
Piezoelectric Fiber Composites with Interdigitated Electrodes
Journal of Intelligent Material Systems and Structures, 1997Piezoelectric Fiber Composites were previously introduced as an alternative to monolithic piezoceramic wafers for structural actuation applications. This manuscript was an investigation into the improvement of piezoelectric fiber composite performance through a nonconventional electroding scheme.
Aaron A. Bent, Nesbitt W. Hagood
openaire +1 more source
Dielectrophoretic liquid lens driven by interdigitated sidewall electrodes
Optics Letters, 2023This paper proposes a dielectrophoretic (DEP) liquid lens that is driven by interdigitated electrodes distributed on the sidewalls and has a structure similar to that of the electrowetting one produced by the company Corning.
Tao Chen +4 more
openaire +2 more sources
Interdigitated electrode modelling for applications in dielectrophoresis
2011 IEEE ICMTS International Conference on Microelectronic Test Structures, 2011Electrical test structures have been designed to enable the characterisation of interdigitated electrode structures in conductive solutions, as used in dielectrophoresis. Test masks have been fabricated to explore the impact of array size, finger separation and solution conductivity on the applied electric field.
C. Chung +5 more
openaire +1 more source
A CMOS Lock-In-based Read-out for Interdigitated Electrodes
2020 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), 2020An analog lock-in amplifier (LIA) designed to be used in portable sensing applications for high-resolution voltage/current detection is presented. Fully differential circuits for signal amplification and embedded high pass filtering were used in order to increase noise rejection reaching a CMRR at 100 kHz of 109 and 149 dB and low input-referred noise <
Paulina Mariana Maya-Hernández +4 more
openaire +1 more source
Fabrication of masks for evaporated interdigital electrodes
Journal of Physics E: Scientific Instruments, 1978A simple method for the fabrication of interdigital evaporation masks is described. The accuracy of the electrode separation is better than 5% at a separation of 0.2 mm. A minimum electrode width of 0.1 mm can be achieved with this method.
B P Blumich, R Germer
openaire +1 more source
A low-frequency resonator with interdigital electrodes
International Journal of Electronics, 1984A low-frequency resonator is described. The resonator, operating in a flexural mode, has interdigital electrodes on one surface of a thin piezoelectric ceramic plate. The interdigital electrodes are used as terminal electrodes of a one-port resonator as well as for poling treatment.
KOHJI TODA, KOICHI MIZUTANI
openaire +1 more source
Electrode Resistance Effects in Interdigital Transducers
IEEE Transactions on Microwave Theory and Techniques, 1974A distributed RC circuit model is used to describe an interdigital electrode transducer (IDT) having finite conduction in the electrode stripes. The distributed circuit is described by a set of differential equations whose solutions yield the current and voltage distributions along the aperture of the IDT.
openaire +1 more source