Results 301 to 310 of about 964,145 (356)
Some of the next articles are maybe not open access.

Optimization & Characterization of Interdigitated Electrodes for Microbial Growth Monitoring

Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2021
This study optimally designed and implemented highly sensitive microscale interdigitated electrodes (IDEs) to monitor microorganisms' growth in diverse environments. Gold interdigitated electrodes (AuIDE) with 4 mm×4 mm effective sensing area and varying
N. Hosseini   +5 more
semanticscholar   +1 more source

Crosslinked PEDOT:PSS Organic Electrochemical Transistors on Interdigitated Electrodes with Improved Stability

, 2021
The influence of gate voltage in the off state (Vg,off) on the stability of the transfer curve of an organic electrochemical transistor (OECT) based on interdigitated electrodes (IDEs) is studied i...
Kan Tang, W. Miao, Song Guo
semanticscholar   +1 more source

3D nanogap interdigitated electrode array biosensors

Analytical and Bioanalytical Chemistry, 2010
Three-dimensional interdigitated electrodes (IDEs) have been investigated as sensing elements for biosensors. Electric field and current density were simulated in the vicinity of these electrodes as a function of the electrode width, gap, and height to determine the optimum geometry. Both the height and the gap between the electrodes were found to have
Kanwar Vikas, Singh   +5 more
openaire   +2 more sources

Cyclic Biamperometry at Micro-Interdigitated Electrodes

Analytical Chemistry, 2011
Cyclic biamperometry was studied as an analytical method for use with commercially available, comb-type, coplanar microinterdigitated electrodes (μIDEs), using the ferri-/ferrocyanide redox couple as a model analyte. The μIDEs studied in this work were made of gold that had been deposited onto a Ti/W adhesion layer on borosilicate glass chips and had 5
Mehdi, Rahimi, Susan R, Mikkelsen
openaire   +2 more sources

Capacitive Stretchable Strain Sensor With Low Hysteresis Based on Wavy-Shape Interdigitated Metal Electrodes

IEEE Sensors Journal, 2021
In this work, a stretchable thin film capacitive strain sensor based on wavy-structured interdigitated metal electrodes is successfully demonstrated. Wavy-shape metal electrodes were patterned using bulk silicon micromachining, endowing the electrodes ...
Siqi Yu, Hongyu Yu
semanticscholar   +1 more source

Submicron Electrode Gaps Fabricated by Gold Electrodeposition at Interdigitated Electrodes

Key Engineering Materials, 2014
Electrodes with submicron gaps are desired for achieving high amplication redoxcycling sensors. In this contribution we report the use of electrodeposition of gold in order todecrease the inter-electrode spacing at interdigitated electrodes. Using this method submicronspacings can be obtained without expensive techniques such as e-beam lithography or ...
van Megen, M.J.J.   +2 more
openaire   +2 more sources

Dielectrophoretic liquid lens driven by interdigitated sidewall electrodes

Optics Letters, 2023
This paper proposes a dielectrophoretic (DEP) liquid lens that is driven by interdigitated electrodes distributed on the sidewalls and has a structure similar to that of the electrowetting one produced by the company Corning. The interdigital electrodes are formed by winding double flexible wire electrodes wrapped in dielectric ...
Tao Chen   +4 more
openaire   +2 more sources

A New Interdigital Electrode Transducer Geometry

IEEE Transactions on Microwave Theory and Techniques, 1974
A new interdigital electrode transducer geometry has been conceived and its theoretical performance verified experimentally. The transducer is composed of sets of electrodes which are connected in series through an offset or "dog-leg" electrode, thereby significantly increasing the electrical impedance of the transducer over that of a conventional one ...
K.M. Lakin, D.W.T. Mih, R.M. Tarr
openaire   +1 more source

Continuum properties from interdigital electrode dielectrometry

IEEE Transactions on Electrical Insulation, 1988
Using a modal approach, a model is derived that makes the interdigital electrode microdielectrometer developed by S. D. Senturia et al. (J. Adhesion, vol.15, p.69-90, 1982) applicable to measuring continuum parameters in a wide range of heterogeneous media.
M.C. Zaretsky, L. Mouayad, J.R. Melcher
openaire   +1 more source

Interdigital Electrode Water Level Sensor

2012
3, 39, KKU Engineering ...
Titinan Tapaonoi   +3 more
openaire   +1 more source

Home - About - Disclaimer - Privacy