Results 301 to 310 of about 942,136 (353)
Some of the next articles are maybe not open access.

Crosslinked PEDOT:PSS Organic Electrochemical Transistors on Interdigitated Electrodes with Improved Stability

, 2021
The influence of gate voltage in the off state (Vg,off) on the stability of the transfer curve of an organic electrochemical transistor (OECT) based on interdigitated electrodes (IDEs) is studied i...
Kan Tang, W. Miao, Song Guo
semanticscholar   +1 more source

Capacitive Stretchable Strain Sensor With Low Hysteresis Based on Wavy-Shape Interdigitated Metal Electrodes

IEEE Sensors Journal, 2021
In this work, a stretchable thin film capacitive strain sensor based on wavy-structured interdigitated metal electrodes is successfully demonstrated. Wavy-shape metal electrodes were patterned using bulk silicon micromachining, endowing the electrodes ...
Siqi Yu, Hongyu Yu
semanticscholar   +1 more source

Fabrication of nano-interdigitated electrodes

SPIE Proceedings, 2003
Thin-film Pt nano interdigitated electrodes realized by combining e-beam lithography and standard photolithography are presented. The resulting nano-IDAs have an active area of 76 μm × 100 μm, an electrode pitch of 785 nm and a gap of 250 nm. The initial results show that this technology is well adapted for the realization of sub-micrometer metallic ...
Nico F. de Rooij   +6 more
openaire   +2 more sources

Cyclic Biamperometry at Micro-Interdigitated Electrodes

Analytical Chemistry, 2011
Cyclic biamperometry was studied as an analytical method for use with commercially available, comb-type, coplanar microinterdigitated electrodes (μIDEs), using the ferri-/ferrocyanide redox couple as a model analyte. The μIDEs studied in this work were made of gold that had been deposited onto a Ti/W adhesion layer on borosilicate glass chips and had 5
Mehdi Rahimi, Susan R. Mikkelsen
openaire   +3 more sources

A New Interdigital Electrode Transducer Geometry

IEEE Transactions on Microwave Theory and Techniques, 1974
A new interdigital electrode transducer geometry has been conceived and its theoretical performance verified experimentally. The transducer is composed of sets of electrodes which are connected in series through an offset or "dog-leg" electrode, thereby significantly increasing the electrical impedance of the transducer over that of a conventional one ...
D.W.T. Mih, K.M. Lakin, R.M. Tarr
openaire   +2 more sources

Fabrication of Interdigital Electrodes for Monolithic Biosensing

2021
Interdigital electrodes/contacts (IDCs) based sensors are widely used in a variety of chemical and biological sensors, which presents promising advantages such as high sensitivity, low electron mobility, enhanced gate conductivity and increased signal to noise ratio.
Nireekshan Kumar Sodavaram   +1 more
openaire   +2 more sources

3D nanogap interdigitated electrode array biosensors

Analytical and Bioanalytical Chemistry, 2010
Three-dimensional interdigitated electrodes (IDEs) have been investigated as sensing elements for biosensors. Electric field and current density were simulated in the vicinity of these electrodes as a function of the electrode width, gap, and height to determine the optimum geometry. Both the height and the gap between the electrodes were found to have
Allison M. Whited   +5 more
openaire   +3 more sources

Interdigitated electrode modelling for applications in dielectrophoresis

2011 IEEE ICMTS International Conference on Microelectronic Test Structures, 2011
Electrical test structures have been designed to enable the characterisation of interdigitated electrode structures in conductive solutions, as used in dielectrophoresis. Test masks have been fabricated to explore the impact of array size, finger separation and solution conductivity on the applied electric field.
Stewart Smith   +5 more
openaire   +2 more sources

A low-frequency resonator with interdigital electrodes

International Journal of Electronics, 1984
A low-frequency resonator is described. The resonator, operating in a flexural mode, has interdigital electrodes on one surface of a thin piezoelectric ceramic plate. The interdigital electrodes are used as terminal electrodes of a one-port resonator as well as for poling treatment.
Kohji Toda, Koichi Mizutani
openaire   +2 more sources

Characterization of Interdigital Electrode Sensors

Surface Engineering and Applied Electrochemistry, 2019
The paper aims to determine the influence of the chosen geometrical parameters of an interdigital sensor and of the measuring cell on the sensor performance, with the final goal of optimizing those parameters. The cell here is a capacitive cell or resistive cell for titration without a particular type.
openaire   +2 more sources

Home - About - Disclaimer - Privacy