Results 51 to 60 of about 7,435 (217)
Interlaboratory comparison of cosmogenic 21 Ne in quartz [PDF]
We performed an interlaboratory comparison study with the aim to determine the accuracy of cosmogenic 21Ne measurements in quartz. CREU-1 is a natural quartz standard prepared from amalgamated vein clasts which were crushed, thoroughly mixed, and sieved into 125–250 μm and 250–500 μm size fractions.
Vermeesch, Pieter +10 more
openaire +4 more sources
Since March 2024, H5N1 highly pathogenic avian influenza (HPAI) has been detected in U.S. dairy cattle. Infectious virus shed in unpasteurized milk, a matrix not previously evaluated for H5N1 detection, makes real-time reverse transcription quantitative ...
Megan R. Miller +16 more
doaj +1 more source
In this article, the author proposed a method for estimating the consensus value of interlaboratory measurement results, which makes it possible to reduce the uncertainty of the consensus value in comparison with the known methods. The method is based on
P. M. Aronov
doaj +1 more source
ABSTRACT Chemical compliance remains the usual endpoint for closing contaminated‐soil remediation projects, although it does not establish recovery of soil function or the durability of the post‐treatment state. This critical review examines when microbiological evidence can contribute to ecological closure decisions.
Mariusz Cycoń
wiley +1 more source
Interlaboratory comparison of the measurement of albumin in urine
Abstract Because of increased interest in the assay of albumin in urine and the sensitivity required to quantify concentrations associated with (a) increased risk of developing end-stage renal disease and cardiovascular disease among people with diabetes and (b) renal damage caused by exposure to nephrotoxic substances, we conducted a ...
P W, Mueller +3 more
openaire +2 more sources
A comparison circulating a standard infrared thermometer, a handy infrared thermometer, and a thermal imager was conducted among eleven participants from the industrial user, academic user, and calibration laboratory communities of these thermometers in ...
Yoshiro Yamada +12 more
doaj +1 more source
Abstract Flow cytometry measures the optical properties of individual cells and has become essential for enumerating and characterizing marine phytoplankton. Yet systematic comparison of measurements across instruments remains limited, hampering data comparison across laboratories and long‐term time series.
Francois Ribalet +10 more
wiley +1 more source
Round robin tests of secondary raw materials: A systematic review of performance parameters
An improved management of secondary raw materials (SRM) is a crucial contribution for a circular economy and necessitates knowledge about the composition of wastes and SRM.
Korf Nathalie +2 more
doaj +1 more source
ABSTRACT The review examines the evolution of chemical ionization mass spectrometry (CI‐MS), a technique developed in 1966 by Field and Munson. CI is a soft‐ionization method that produces more intense molecular ions with less fragmentation than electron ionization (EI).
Malvika Dutt +4 more
wiley +1 more source
Data‐Independent Acquisition Mass Spectrometry in Tumor Classification and Cancer Biomarker Research
Abstract Cancer treatment is far from optimal also because current classification systems do not reflect the complex molecular status of the tumor and its phenotype in sufficient detail. To construct molecular tumor classifiers, omics tools provide complex molecular data reflecting many aspects from genotype to phenotype.
Jan Simonik +3 more
wiley +1 more source