Results 111 to 120 of about 41,195 (241)
ABSTRACT Purpose In diffusion MRI, vasogenic edema manifests as a major fraction of isotropic water that dilutes the anisotropic intra‐axonal portion of the signal. Many tractography algorithms mistake vasogenic edema for the white matter boundary and terminate tracking to prevent producing spurious streamlines.
Patryk Filipiak +6 more
wiley +1 more source
Chemical Shift Separated and Compensated Ultra‐Short Echo‐Time Imaging
ABSTRACT Purpose To develop a modified binomial excitation scheme for ultra‐short echo‐time (UTE) imaging that allows for the separation of water and fat signals and the correction of chemical shift artifacts. Methods Theoretical derivation and numerical Bloch simulations were performed for a modified water‐excitation binomial pulse scheme to calculate
Martin Krämer +3 more
wiley +1 more source
ABSTRACT Purpose To develop a denoising technique for displacement encoding with stimulated echoes (DENSE) MRI that improves spatial resolution, efficiency, and accuracy, and enhances accessibility by implementing DENSE MRI at 0.55 T. Methods We developed a low‐rank denoising technique, which leverages multidimensional spiral cine DENSE MRI data for ...
Shu‐Fu Shih +9 more
wiley +1 more source
ABSTRACT Purpose This study aimed to improve the analysis of the left ventricular (LV) blood pool hyperpolarized [1‐13C]pyruvate signal for a more reliable quantification of downstream metabolic outcome. Methods Hyperpolarized [1‐13C]pyruvate magnetic resonance spectroscopic images were acquired dynamically at 3 Tesla in 106 participants (NCT03685175).
Fatemeh Khashami +30 more
wiley +1 more source
ABSTRACT Purpose To improve slice profile consistency across echo trains in turbo spin echo (TSE) imaging, thereby reducing image blurring and increasing the accuracy of multi echo spin echo T2$$ {T}_2 $$ mapping. Methods Excitation and refocusing RF pulses were optimized for TSE using a differentiable extended phase graph model that incorporates the ...
Madison M. Augelli +3 more
wiley +1 more source
Free‐Breathing Magnetization Transfer Imaging of the Lung at 0.55 T Using bSTAR
ABSTRACT Purpose To develop a clinically applicable method for magnetization transfer (MT) imaging of the lung at 0.55 T. Methods MT imaging of the chest was explored in healthy volunteers at 0.55 T using a self‐gated 3D half‐radial dual‐echo balanced steady‐state free precession sequence (bSTAR), a 2D multi‐slice gradient echo method (GRE) acquired in
Alexandra Braun +5 more
wiley +1 more source
Visual and tactile motion cues enhance the categorisation of novel object shapes. [PDF]
Seveso MA +4 more
europepmc +1 more source
ABSTRACT Purpose To improve accuracy and repeatability of myocardial 23Na quantification in cardiac MRI at 7 T by combining retrospective respiratory and cardiac motion correction with a novel anatomy‐based B1 bias field correction. Methods In this study, a dual‐nuclear interleaved 23Na/1H MRI sequence at 7 T was applied.
Laurent Ruck +10 more
wiley +1 more source
Current sensorless MPPT method with battery management for PV based single phase standalone system. [PDF]
Genc N +4 more
europepmc +1 more source
ABSTRACT Purpose To develop and validate an accelerated phase‐modulated ultrashort echo time (PM‐UTE) sequence for volumetric T2 and adiabatic T1ρ (AdiabT1ρ) mapping of both short‐ and long‐T2 tissues in the knee joint. Methods The proposed method estimates and removes the T1‐dependent component from a single reference acquisition, eliminating repeated
Jiyo S. Athertya +7 more
wiley +1 more source

