Results 171 to 180 of about 451 (255)

Scalable generalized meta-spanners enabling parallel multitasking optical manipulation. [PDF]

open access: yesSci Adv
Li T   +14 more
europepmc   +1 more source

Navigator‐Based Slice Tracking for Multiband Accelerated Liver DWI

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 2, Page 852-861, August 2026.
ABSTRACT Purpose Clinical liver diffusion‐weighted imaging (DWI) suffers from long measurement time and respiratory motion. In this study, we employ a navigator‐based slice tracking technique (NAV) to prospectively compensate for respiratory motion in multiband (MB) accelerated liver DWI.
Ke Zhang   +8 more
wiley   +1 more source

Signal and Contrast Optimization With Predicted Excitations (SCOPE) for Accelerating Large FOV Body Imaging at UHF

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 2, Page 635-649, August 2026.
ABSTRACT Purpose Large FOV turbo‐spin‐echo (TSE) imaging at ultra‐high field (UHF) remains challenging due to B1+ inhomogeneity and peak specific absorption rate (pSAR) limitations. This work presents a new time‐interleaved acquisition of modes (TIAMO) framework called SCOPE (Signal and Contrast Optimization with Predicted Excitations), which overcomes
Tobey D. Haluptzok   +2 more
wiley   +1 more source

The MAGnetometers for Innovation and Capability (MAGIC) Technology Demonstration Payload. [PDF]

open access: yesSpace Sci Rev
Miles DM   +21 more
europepmc   +1 more source

Using U‐Nets to Predict the Effects of Head Motion on Simulated Specific Absorption Rate for Ultra‐High Field Magnetic Resonance Imaging With Parallel Transmission

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 2, Page 650-665, August 2026.
ABSTRACT Purpose Ultrahigh‐field MRI requires careful management of the specific absorption rate (SAR), which is subject and subject‐position dependent. Within‐scan subject motion may exacerbate local SAR exposure, necessitating large safety margins to prevent SAR underestimation, which hampers imaging performance.
Katherine Anna Blanter   +4 more
wiley   +1 more source

Single‐Breathhold 3D MR Elastography in the Liver, With Simultaneous R2* and PDFF Mapping

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 2, Page 682-697, August 2026.
Purpose To develop a sequence for the rapid acquisition of MR elastography (MRE) parameters in 3D, with simultaneous measurement of proton‐density fat fraction (PDFF) and R2* for multiparametric assessment of liver disease. Methods The proposed sequence uses an interleaved motion‐encoding scheme to acquire 3D volumes of all motion encodings and wave ...
Donovan P. Tripp   +10 more
wiley   +1 more source

Design of Differential Single‐Block and Multi‐Block Presaturated Ultrashort Echo Time Pulse Sequences for Fast and Flexible Short‐T2 Imaging

open access: yesMagnetic Resonance in Medicine, Volume 96, Issue 2, Page 711-726, August 2026.
ABSTRACT Purpose Ultrashort echo time (UTE) techniques are essential for the magnetic resonance imaging of short‐T2 signals. Current UTE techniques are time‐consuming and often require the acquisition of an inflexible volume. In this work, we implement new UTE sequences—differential single‐block presaturated UTE (δSB‐UTE) and differential multi‐block ...
Jason A. Reich   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy