Results 161 to 170 of about 1,253 (283)
ABSTRACT Purpose 4D cardiac cine is a powerful tool for comprehensive cardiac function assessment; however, current methods rely on regular breathing and are sensitive to bulk motion and arrhythmia. We aim to develop a 4D cardiac cine approach that requires no patient cooperation and is robust to irregular breathing, bulk motion, and cardiac arrhythmia.
Ye Tian +4 more
wiley +1 more source
Rapid adiabatic couplers with arbitrary split ratios for broadband DWDM interleaver application. [PDF]
Choi D, Kim WJ, Sohn YI.
europepmc +1 more source
High throughput resource efficient reconfigurable interleaver for MIMO WLAN application. [PDF]
Upadhyaya BK, Pramanik PKD, Sanyal SK.
europepmc +1 more source
Relationship Between Mean Kärger Model Water Exchange Rate and Intercellular Water Transition Rate
ABSTRACT Purpose To derive a quantitative relationship between the mean Kärger model (KM) water exchange rate and the mean intercellular water transition rate applicable to brain and other complex biological tissues. Theory and Methods The mean KM water exchange rate applies to any KM, accommodates an arbitrary number of compartments, and can be ...
Jens H. Jensen +3 more
wiley +1 more source
<i>Listeria monocytogenes</i>: A Continuous Global Threat in Ready-to-Eat (RTE) Foods. [PDF]
Yangchen J +4 more
europepmc +1 more source
ABSTRACT Purpose Widespread adoption and methodological advancement of magnetic resonance fingerprinting (MRF) are limited by the lack of unified, reproducible implementation frameworks and fragmented open‐source tools. To address these barriers, we introduce OpenMRF—a comprehensive Pulseq‐based solution—designed to enable standardized and transferable
Tom Griesler +17 more
wiley +1 more source
ABSTRACT Purpose To develop, optimize, and characterize a respiratory motion‐resolved free‐running isotropic 3D carotid vessel wall T1 mapping technique named CARISMAT1C. Methods An inversion‐recovery gradient‐echo free‐running pulse sequence with interleaved double flip‐angle (2FA) was implemented, and an extended‐phase‐graph dictionary was used to ...
Isabel Montón Quesada +7 more
wiley +1 more source
Time-resolved certification of frequency-bin entanglement over multi-mode channels. [PDF]
Vinet S +9 more
europepmc +1 more source
ABSTRACT Purpose To improve brain water content measures relative to cerebrospinal fluid (CSF) by including a rapid T1‐independent sequence to correct for CSF T1 errors. Methods Proton density (PD) was estimated from a 3D multiple echo gradient echo sequence by extrapolating to TE = 0 and then correcting for T1 losses using a T1 map from 3D MP2RAGE. To
Kiarash Jalali +3 more
wiley +1 more source
Enhanced 3D Filter‐Exchange Imaging Using Multi‐Slab Acquisition
ABSTRACT Purpose Starting from the implementation of a single‐slice FEXI sequence, a 3D method was developed to accelerate a FEXI experiment and acquire a multi‐slice volume. Methods 3D multi‐slab FEXI divides the volume of interest into different slabs.
Jacopo Frignani +3 more
wiley +1 more source

