Results 131 to 140 of about 5,953 (266)

Fast Localized Calibration for Spatial‐Spectral Excitation Without Fly‐Back Gradients

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose Standard spatial‐spectral excitation pulses apply a fly‐back gradient between sub‐pulses, limiting, for example, how thin the slices can be (> 4 mm). Without fly‐back gradients, slices can be as thin as 1.7 mm but require a phase calibration for the sub‐pulses with inverted gradients due to system imperfections.
Michael Schär   +3 more
wiley   +1 more source

Generative MR Multitasking With Complex‐Harmonic Cardiac Encoding: Bridging the Gap Between Gated Imaging and Real‐Time Imaging

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To develop a unified image reconstruction framework that bridges real‐time and gated cardiac MRI, including quantitative MRI. Methods We introduce generative multitasking, which learns subject‐ and dataset‐specific implicit neural temporal bases from sequence timings and an interpretable latent space for cardiac and respiratory motion.
Xinguo Fang, Anthony G. Christodoulou
wiley   +1 more source

Foundry-enabled wafer-scale characterization and modeling of silicon photonic DWDM links. [PDF]

open access: yesNanophotonics
Parsons R   +8 more
europepmc   +1 more source

Comparison of Amplitude‐ and Amplitude‐Frequency‐Modulated Pulses for Outer Volume Suppression in Cardiac MRI: Application to Myocardial T2$$ {T}_2 $$ Mapping

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To evaluate single‐ and dual‐band pulse modules for suppressing extra‐cardiac signal in cardiac MRI, and test their applicability for time‐efficient imaging with reduced FOV in myocardial T2$$ {T}_2 $$ mapping at 3 T. Methods Outer Volume Suppression (OVS) was implemented using two regional saturation slabs, along the phase‐encoding ...
Ayda Arami   +8 more
wiley   +1 more source

Sparsity and memory constraints interact with training sequence to bias learning of associative maps. [PDF]

open access: yesNeuropsychologia
Noh SM   +5 more
europepmc   +1 more source

Image Encoding With Blipped Gradients in an Echo Train

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose An MRI scanner was designed and built to encode k$$ k $$‐space points in the spin echoes occurring between 180∘$$ 18{0}^{\circ } $$ pulses in an echo train by using blipped B0$$ {B}_0 $$ gradient pulses applied just prior to those spin echoes.
Logi Vidarsson, Gordon E. Sarty
wiley   +1 more source

Self‐calibrated B1+ and B0 Field Inhomogeneities Estimation (SAFE) in 3D Magnetic Resonance Fingerprinting

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To develop SAFE, a self‐calibrated framework to estimate B1+ and B0 field inhomogeneities directly from conventional magnetic resonance fingerprinting (MRF) acquisitions and improve its quantification accuracy. Methods SAFE utilized a two‐step approach. First, two physics‐informed image markers are extracted from the MRF data to create
Mengze Gao   +13 more
wiley   +1 more source

Home - About - Disclaimer - Privacy