Results 231 to 240 of about 385,490 (402)

Flow‐suppressed 2D spin‐echo imaging with high tolerance to B1 inhomogeneity using hyperbolic secant pulses

open access: yesMagnetic Resonance in Medicine, EarlyView.
Abstract Purpose To demonstrate flow‐suppressed two‐dimensional (2D) spin‐echo and spin‐echo diffusion echo‐planar imaging (EPI) sequences using hyperbolic secant (HS) pulses for both π/2 excitation and π refocusing. Theory and Methods A theoretical framework to derive phase dispersion of moving spins under π/2 excitation and π refocusing using HS ...
Jae‐Youn Keum   +3 more
wiley   +1 more source

Combined angiography and perfusion using radial imaging and arterial spin labeling with structural contrast

open access: yesMagnetic Resonance in Medicine, EarlyView.
Abstract Purpose To develop a non‐contrast MRI method for the simultaneous acquisition of time‐resolved 3D angiographic, perfusion, and multi‐contrast T1‐weighted structural brain images in a single 6 min acquisition. Methods The proposed combined angiography and perfusion using radial imaging and arterial spin labeling with structural contrast (CAPRIA+
Thomas W. Okell   +2 more
wiley   +1 more source

Ex vivo human brain volumetry: Validation of MRI measurements

open access: yesMagnetic Resonance in Medicine, EarlyView.
Abstract Purpose The volume of in vivo human brains is determined with various MRI measurement tools that have not been assessed against a gold standard. The purpose of this study was to validate the MRI brain volumes by scanning ex vivo, in situ specimens, which allows the extraction of the brain after the scan to compare its volume with the gold ...
Amy Gérin‐Lajoie   +7 more
wiley   +1 more source

Molecular hydrogen-rhodiola as an adjuvant therapy for ischemic stroke in internal carotid artery occlusion: A case report. [PDF]

open access: yesOpen Med (Wars)
Chang FH   +12 more
europepmc   +1 more source

Spontaneous dissecting aneurysms of the internal carotid and vertebral arteries--two case reports. [PDF]

open access: bronze, 1985
JL Mas   +5 more
openalex   +1 more source

Bidirectional crusher gradient method to estimate the labeling efficiency of pseudo‐continuous arterial spin labeling MRI in mice

open access: yesMagnetic Resonance in Medicine, EarlyView.
Abstract Purpose To develop an experimental method for measuring the labeling efficiency of pseudo‐continuous arterial spin labeling (pCASL) MRI in mice. Methods We propose a method using bidirectional crusher gradients to modulate vascular signals in the azygos pericallosal artery (azPA) of the mouse brain, applied with and without pCASL labeling. The
Xiuli Yang   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy