Shear‐Isolating Actuation System for Exosuit Using Movable Pulley With Webbing‐Driven Mechanism
Tendon‐driven exosuits can chafe the skin because the moving tendon slides against the wearer. A shear‐isolating actuation system combining a movable pulley with flat‐profile webbing keeps the body‐contacting tendon layer stationary, relocating relative motion away from the skin. The compact 145‐g actuator delivers 150 N of assistance, and benchtop and
Kyeongmin Lim +5 more
wiley +1 more source
Comparative Outcomes of Hip Fractures in Centenarians Compared to Non-Centenarians. [PDF]
Çevik HB +7 more
europepmc +1 more source
Robotics in Ionizing Radiation Environments: Vulnerabilities, Hardening, and Future Directions
Radiation exposure causes cumulative degradation in robotic sensors, actuators, and electronic logic, often leading to undetected failures. This study maps component vulnerabilities, evaluates hardening and shielding strategies, and identifies testing gaps that must be addressed to enable next‐generation radiation‐tolerant robotic systems.
Francis A. K. Djirackor +4 more
wiley +1 more source
Femoral neck fractures in patients with prior lower-limb amputation: a two-case series and narrative review of surgical decision-making. [PDF]
Li D, Yu H, Yang W.
europepmc +1 more source
This study investigates how the internal structure of fiber‐reinforced ceramic composites affects their resistance to damage. By combining 3D X‐ray imaging with acoustic emission monitoring during mechanical testing, it reveals how silicon distribution influences crack formation.
Yang Chen +7 more
wiley +1 more source
Perspective: Hollow Core Optical Fibres for Ultraviolet and Visible Wavelengths
Hollow core optical fibres bypass material constraints that limit optical fibres at ultraviolet and visible wavelengths. However, their challenging fabrication has limited their development, and significant gains in performance remain possible. In this perspective we outline approaches to enable the next generation of fibres for shorter wavelengths ...
Robbie Mears +5 more
wiley +1 more source
Vegetarian and Vegan Diets and the Risk of Hip Fracture in Adults: A Systematic Review and Meta-analysis. [PDF]
Ballarin RS +7 more
europepmc +1 more source
This study combines full‐field tomography with diffraction mapping to quantify radial (ε002$\varepsilon _{002}$) and axial (ε100$\varepsilon _{100}$) lattice strain in wrinkled carbon‐fiber specimens for the first time. Radial microstrain gradients (−14.5 µεMPa$\varepsilon \mathrm{MPa}$−1) are found to signal damage‐prone zones ahead of failure, which ...
Hoang Minh Luong +7 more
wiley +1 more source
Effects of variable bolt position of femoral neck system on Pauwels III fractures with superior femoral neck bone defect: multimodal biomechanical and clinical study. [PDF]
Zhang Q +10 more
europepmc +1 more source

