Results 41 to 50 of about 4,072,286 (225)

Inverted internal limiting membrane flap technique versus complete internal limiting membrane peeling in large macular hole surgery: a comparative study

open access: yesBMC Ophthalmology, 2020
Background To compare the anatomical and functional outcomes of the inverted internal limiting membrane (ILM) flap technique and the complete ILM removal in the treatment of large stage 4 macular hole (MH) > 400 μm and to evaluate reconstructive ...
Prithvi Ramtohul   +3 more
doaj   +1 more source

The Role of Inverted Internal Limiting Membrane Flap in Macular Hole Closure

open access: yesInvestigative Opthalmology & Visual Science, 2017
To investigate the mechanism of macular hole (MH) closure following the inverted internal limiting membrane (ILM) technique.We performed the inverted ILM flap surgical technique as an experimental MH model in monkeys, and investigated the process of MH closure immunohistochemically. We then investigated the effects of type IV collagen, fibronectin, and
Yusuke, Shiode   +12 more
openaire   +3 more sources

Comparative analysis of the oct and microperimetry data to assess the state of the central regions of the retina following the relapse of a macular rupture [PDF]

open access: yesКлиническая практика, 2020
Background. In 810% of cases after the surgical treatment, macular ruptures do not close. Aim: to assess the morphological and functional parameters of the macular area following the surgical closing of previously operated macular ruptures using a free ...
Mikhail M. Shishkin   +5 more
doaj   +1 more source

INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE FOR MACULAR HOLE COEXISTENT WITH RHEGMATOGENOUS RETINAL DETACHMENT

open access: yes, 2022
To report the clinical features and treatment outcomes of patients with macular hole coexistent with rhegmatogenous retinal detachment surgically treated with pars plana vitrectomy and inverted internal limiting membrane flap technique.
Stappler, Theodor   +14 more
core   +1 more source

Free autologous internal limiting membrane transplantation in the treatment of large macular hole [PDF]

open access: yesInternational Journal of Ophthalmology, 2019
We evaluated the clinical efficacy of free internal limiting membrane (ILM) flap transplantation for the treatment of large macular hole over 500 μm in 42 consecutive patients.
Fei-Yan Ma   +3 more
doaj   +1 more source

Technology of Inverted Internal Limi ting Membrane Flap in Surgery of Primary Through Macular Retinal Holes. Literature Review

open access: yesOftalʹmologiâ
A review of the literature describes various approaches to peeling the internal limiting membrane of the retina in the surgical treatment of penetrating macular holes.
N. M. Shilov   +4 more
doaj   +1 more source

Comparative efficacy evaluation of inverted internal limiting membrane flap technique and internal limiting membrane peeling in large macular holes: a systematic review and meta-analysis

open access: yesBMC Ophthalmology, 2020
Background The purpose of this study was to compare the anatomical and visual outcomes of inverted internal limiting membrane (ILM) flap technique and internal limiting membrane peeling in large macular holes (MH).
Yu Shen   +3 more
doaj   +1 more source

Surgical approach to pediatric optic disc pit maculopathy: a case report

open access: yesUkrainian Journal of Ophthalmology
Purpose: To evaluate postoperative results of pars plana vitrectomy combined with an inverted internal limiting membrane-flap technique and intravitreal injection of viscoelastic material for optic disc pit maculopathy complicated by serous macular ...
M.M. Umanets , N.F. Bobrova, I.P. Dovhan
doaj   +1 more source

Rational Tuning of Hygroscopic Oscillation of Stacked Nanoflake Assemblies for Continuous Ambient Energy Harvesting

open access: yesAdvanced Materials, EarlyView.
Stacked nanoflake assembly (SNA) membranes can oscillate autonomously, offering opportunities for soft actuation and energy harvesting. This work uncovers the physical mechanism behind the sustained oscillation of SNA membranes in gradient humidity and identifies three governing dimensionless parameters, enabling rational design for optimizing SNA ...
Zijing Zhang   +5 more
wiley   +1 more source

Sustainable Poly(Lactic Acid)/Graphene Oxide Bioelectronic Platform for Neurotransmitters Sensing and Tunable Stimulation of Astrocytes

open access: yesAdvanced Materials, EarlyView.
This work introduces sustainable PLA/graphene oxide bioelectronic interfaces featuring electrodes with tunable conductivity and strong electrocatalytic performance. These platforms were used to implement a new method for tuning astrocyte Ca2+ signaling and for the efficient detection of key biomarkers.
Alessandra Scidà   +15 more
wiley   +1 more source

Home - About - Disclaimer - Privacy