Results 51 to 60 of about 12,129 (222)

The Effect of Contemporary Brachytherapy Practices on Prognosis in Women with Locally Advanced Cervical Cancer

open access: yesCurrent Oncology, 2023
(1) Background: Over the past two decades use of new imaging modalities and the adaptation of applicators have allowed for advances in volumetric (3D) imaging-based brachytherapy practices for patients with locally advanced cervical cancer.
Janna J. Laan   +7 more
doaj   +1 more source

A systematic review of treating recurrent head and neck cancer: a reintroduction of brachytherapy with or without surgery. [PDF]

open access: yes, 2018
Purpose: To review brachytherapy use in recurrent head and neck carcinoma (RHNC) with focus on its efficacy and complication rates. Material and methods: A literature search of PubMed, Ovid, Google Scholar, and Scopus was conducted from 1990 to 2017 ...
Bar-Ad, Voichita   +10 more
core   +1 more source

Radioactive seed immobilization techniques for interstitial brachytherapy [PDF]

open access: yes, 2008
Purpose In prostate brachytherapy, seeds can detach from their deposited sites and move locally in the pelvis or migrate to distant sites including the pulmonary and cardiac regions.
Buzurovic, I.   +10 more
core   +2 more sources

Accelerated partial breast irradiation utilizing brachytherapy: patient selection and workflow

open access: yesJournal of Contemporary Brachytherapy, 2016
Accelerated partial breast irradiation (APBI) represents an evolving technique that is a standard of care option in appropriately selected woman following breast conserving surgery.
Chirag Shah   +4 more
doaj   +1 more source

Safety and Efficacy of Salvage Treatment for Recurrent Nasopharyngeal Carcinoma: A Single‐Center Retrospective Study Over 10 Years

open access: yesCancer Medicine, Volume 15, Issue 2, February 2026.
ABSTRACT Background To analyze survival outcomes and identify prognostic factors in patients with locoregionally recurrent nasopharyngeal carcinoma (NPC) receiving salvage treatment, and to evaluate the safety profile of re‐irradiation. Methods We retrospectively analyzed clinical data from 95 patients with recurrent NPC (rM0) who were diagnosed and ...
Yanrong Luo   +4 more
wiley   +1 more source

Proof-of-concept of real-time electromagnetic guidance for gynecologic interstitial catheters in high dose rate brachytherapy

open access: yesPhysics and Imaging in Radiation Oncology
Background and Purpose: The addition of interstitial needles to intracavitary gynecologic (GYN) high dose rate (HDR) brachytherapy has been shown to improve target coverage and organs-at-risk (OAR) sparing.
Audrey Cantin   +5 more
doaj   +1 more source

Focal Spot, Summer 1992 [PDF]

open access: yes, 1992
https://digitalcommons.wustl.edu/focal_spot_archives/1061/thumbnail ...

core   +1 more source

Generation of 3D reference dosimetric datasets towards adoption of model‐based dose calculations for permanent implant prostate brachytherapy

open access: yesMedical Physics, Volume 53, Issue 2, February 2026.
Abstract Purpose This work aims to create and validate a comprehensive set of test cases and 3D reference dosimetric datasets for model‐based dose calculation algorithms (MBDCAs) in permanent implant prostate brachytherapy. These test cases address the limits of the standard TG‐43 formalism towards improving dose evaluations in prostate cancer ...
Fatemeh Akbari   +8 more
wiley   +1 more source

Oral cancer: current role of radiotherapy and chemotherapy [PDF]

open access: yes, 2013
The term oral cavity cancer (OSCC) constitutes cancers of the mucosal surfaces of the lips, floor of mouth, oral tongue, buccal mucosa, lower and upper gingiva, hard palate and retromolar trigone.
Huang, Shao Hui, O'Sullivan, Brian
core   +1 more source

Combining flat‐panel imaging with internal BB markers for precise HDR brachytherapy source localization: A simulation study

open access: yesMedical Physics, Volume 53, Issue 2, February 2026.
Abstract Background High Dose Rate (HDR) brachytherapy delivers concentrated radiation to the tumor by placing a high‐dose‐rate radioactive source directly inside the target. However, the sharp dose falloff also increases susceptibility to errors and uncertainties.
Yibin Ling   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy