Results 1 to 10 of about 1,152,977 (211)
Loss of Guide Wire: A Rare Complication of Intra-Aortic Balloon Pump Insertion
At the final stages of a coronary artery bypass graft operation on a 64-year-old man, an experienced physician attempted to insert an intra-aortic balloon pump into the femoral artery via the Seldinger technique. However, while the balloon pump was being
Manouchehr Hekmat +2 more
doaj +1 more source
The increasing use of the intra aortic balloon pump is attributed to the relatively easy percutaneous insertion and the low threshold of use over the past few years, especially in elderly patients with multi-vessel diseases and an affected ejection ...
Soo Alan +2 more
doaj +1 more source
Background: In modern healthcare, decision-making processes are becoming increasingly data-driven, aiming to optimize patient care and resource allocation.
Zainab A. Wajeeh +3 more
doaj +1 more source
Undiagnosed aortic dissection in patient with intra-aortic balloon pump
60 years old lady presented with chest pain and was admitted in local hospital. Electrocardiogram was suggestive of anterior myocardial ischemia. Patient underwent coronary angiography which revealed severe triple vessles coronary artery disease.
Monish S Raut +2 more
doaj +1 more source
We report a typical case of takotsubo cardiomyopathy developed in a 34 year female post-laparoscopic salpingectomy. The prompt insertion of intra-aortic-balloon-pump (IABP) with supportive medical treatment restored her haemodynamic within three days ...
Venkata Nageswara Rao Goteti +2 more
doaj +1 more source
Objective: To study the reduction in platelet count in patients after coronary artery bypass grafting having IABP placed peri operatively with and without IABP placed. Study Design: Descriptive Study.
Qurrat-Ul-Ain Amjad +3 more
doaj +2 more sources
O balão intra-aórtico é um dispositivo de assistência circulatória mecânica utilizado nos casos de falência ventricular per-operatória. Neste estudo foram seguidos todos os pacientes submetidos a inserção de balão intra-aórtico durante 22 meses, no ...
Fabiano G. JUCÁ +4 more
doaj +1 more source
Key Clinical Message Electrocardiographic findings at first medical contact and direct transfer to the catheterization laboratory are important in acute total occlusion of the left main coronary artery. Simultaneous emergency angioplasty and intra‐aortic
Vojko Kanic, Damijan Vokac, Samo Granda
doaj +1 more source
Hemostasis of a large-diameter sheath is sometimes problematic, especially for patients with limited approach sites. Here, we describe an effective and safe endovascular method for hemostasis of the femoral artery via the dorsalis pedis artery.
Hiromi Miwa +7 more
doaj +1 more source
Perioperative use of Impella device in very high-risk coronary artery bypass grafting
This case study presents a high-risk coronary artery bypass grafting (CABG) patient with a recent anterior wall myocardial infarction and severely impaired left ventricular function.
P. L. N. Kapardhi +3 more
doaj +1 more source