Results 11 to 20 of about 4,754 (178)

Intra-aortic Balloon Pump [PDF]

open access: yes, 2020
This chapter describes the intra-aortic balloon pump (IABP), which is the single most widely used mechanical circulatory assist device available today. Counterpulsation refers to balloon inflation in diastole and deflation in early systole: this results in increased coronary blood flow, left ventricular afterload reduction, and increased end-organ ...
Christopher Choi, Amirali Masoumi
  +5 more sources

Variability of extracorporeal cardiopulmonary resuscitation practice in patients with out‐of‐hospital cardiac arrest from the emergency department to intensive care unit in Japan

open access: yesAcute Medicine & Surgery, 2021
Aim A lack of known guidelines for the provision of extracorporeal cardiopulmonary resuscitation (ECPR) to patients with out‐of‐hospital cardiac arrest (OHCA) has led to variability in practice between hospitals even in the same country.
Toru Hifumi   +40 more
doaj   +1 more source

A case of fulminant myocarditis with full recovery after a 38‐h sustained asystole

open access: yesClinical Case Reports, 2023
Key Clinical Message Even if cardiac rhythm deteriorated to asystole in the clinical course of fulminant myocarditis, cardiac function may recover, and the patient may be discharged without brain damage, if circulation could be maintained by appropriate ...
Tomohiro Akutsu   +5 more
doaj   +1 more source

Statistical Analysis of IABP-Surgery Data with the Co-use of Anticoagulants, Pulse of Dorsalis Pedis Artery, D-Dimer Data, and Coagulation Function

open access: yesFrontiers in Surgery, 2022
Data analysis was performed on IABP (intra-aortic balloon pump) patients for the use of anticoagulants, pulse of dorsalis pedis artery, D-dimer data, and coagulation function.
Huali Chen   +14 more
doaj   +1 more source

1.6 DETRIMENTAL EFFECTS ON CAROTID PERFUSION OF INTRA-AORTIC BALLOON PUMP SUPPORT

open access: yesArtery Research, 2009
Introduction: Intra-aortic balloon pumping is widely used to augment diastolic coronary perfusion. However, far less is known about its effects on other large arteries. In this study we assessed the effects of intra-arterial balloon pump pressure support
J.E. Davies   +7 more
doaj   +1 more source

Descending aortic calcification increases renal dysfunction and in-hospital mortality in cardiac surgery patients with intraaortic balloon pump counterpulsation placed perioperatively : a case control study [PDF]

open access: yes, 2012
Introduction: Acute kidney injury (AKI) after cardiac surgery increases length of hospital stay and in-hospital mortality. A significant number of patients undergoing cardiac surgical procedures require perioperative intra-aortic balloon pump (IABP ...
Bingold, Tobias Michael   +9 more
core   +2 more sources

Uso do balão intra-aórtico no choque cardiogênico no pós-operatório de cirurgia cardíaca: análise prospectiva durante 22 meses

open access: yesBrazilian Journal of Cardiovascular Surgery, 1998
O balão intra-aórtico é um dispositivo de assistência circulatória mecânica utilizado nos casos de falência ventricular per-operatória. Neste estudo foram seguidos todos os pacientes submetidos a inserção de balão intra-aórtico durante 22 meses, no ...
Fabiano G. JUCÁ   +4 more
doaj   +1 more source

Refractory ventricular arrhythmias during aortic valve replacement and cardiac artery bypass requiring 16 attempts of electrical cardioversion: a case report

open access: yesJA Clinical Reports, 2020
Background We report a patient in whom we failed to suppress ventricular fibrillation (VF) using nifekalant but succeeded using amiodarone during cardiopulmonary bypass (CPB).
Mitsuharu Kodaka   +4 more
doaj   +1 more source

Intra-Aortic Balloon Pump for Patients with Cardiac Conditions: An Update on Available Techniques and Clinical Applications

open access: yesReports, 2019
In this paper, we present a review of the intra-aortic balloon pump, as well as the usage of it in the medical field today. An intra-aortic balloon pump (IABP) is a biomedical device that can assist the heart during unstable angina or after a heart ...
Vanessa M. Limbert, Amir M. Amiri
doaj   +1 more source

Acute torrential mitral regurgitation during transcatheter aortic valve replacement: a case report

open access: yesSurgical Case Reports, 2018
Background Transcatheter aortic valve replacement (TAVR) is a minimally invasive approach to aortic valve replacement. However, critical cardiovascular collapse can occur during the procedure for various reasons.
Yoshiyuki Yamashita   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy