Results 1 to 10 of about 2,462 (79)
Study of the energy efficiency of various drive systems of an innovative implantable left ventricular assist device [PDF]
This paper presents the results of studies of the energy efficiency of an innovative implantable left ventricular assist device. One of the advantages of the proposed LVAD is in cases where end-stage left ventricular failure is accompanied by mitral ...
Ryszard Jasinski +3 more
doaj +2 more sources
This paper presents the results of experimental performance of an innovative left ventricular assist device working on a specially designed test stand. The introduced invention is mainly applied for supporting the heart in patients with end-stage heart ...
Krzysztof Tesch +3 more
doaj +1 more source
The use of iodine contrast agents is one possible limitation in cryoballoon ablation (CBA) for atrial fibrillation (AF). This study investigated intracardiac echography (ICE)-guided contrast-free CBA.The study was divided into 2 phases. First, 25 paroxysmal AF patients (Group 1) underwent CBA, and peri-balloon leak flow velocity (PLFV) was assessed ...
Suzuki, Atsushi +16 more
openaire +3 more sources
This paper presents the results of a study on the effect of vascular lumen reduction on the performance of an innovative implantable LVAD (left ventricular assist device).
Ryszard Jasinski +3 more
doaj +1 more source
This paper presents the operation of an innovative left ventricular assist device under various resistances and operating frequencies. The operating principle of the device is based on pulsatile blood flow, which is forced by a suction–discharge device ...
Ryszard Jasinski +3 more
doaj +1 more source
Why we should be counting in the cardiac catheter lab: A discussion paper
Standards that are routinely applied in the operating suite may not be applied in the cardiac catheter laboratory. One such standard is the management of accountable items such as swabs, surgical instruments, sharps and sheaths. Well-known standards and
Stephanie Biggs, Paula Foran
doaj +1 more source
Background In this case report, we describe a novel application of the technique of ‘dual-balloon assisted’ cannulation and embolisation of a high flow arterial venous fistula (AVF) in transplant kidney, where attempts at standard and previously ...
Sara ffrench-Constant +5 more
doaj +1 more source
Resumo: Introdução e objetivos: A intervenção coronária percutânea (ICP) com balão eluidor de fármaco (DEB) tem vindo a ser utilizada no tratamento da reestenose intra-stent (RIS) e na doença coronária de pequenos vasos.
Rita Calé +12 more
doaj +1 more source
Background Outcomes from cardiopulmonary resuscitation (CPR) following sudden cardiac arrest are suboptimal. Postresuscitation targeted temperature management has been shown to have benefit in subjects with sudden cardiac arrest due to ventricular ...
Matt T. Oberdier +10 more
doaj +1 more source
Background: Coronary obstruction (CO) during transcatheter aortic valve replacement (TAVR) is associated with significant morbidity and mortality. UNICORN (Undermining Iatrogenic Coronary Obstruction with Radiofrequency Needle) is a novel technique ...
Mostafa Naguib, MD +9 more
doaj +1 more source