Results 91 to 100 of about 114,154 (302)
A composite hydrogel (C‐gel) incorporating PEG‐b‐PPS filomicelles enables localized in situ gelation and sustained nanocarrier release within the anterior chamber. The filamentous structure promotes spatial confinement of multi‐arm polymer crosslinking, even upon injection into large aqueous volumes, and gradually transitions into spherical micelles ...
Hyeohn Kim +6 more
wiley +1 more source
Rhegmatogenous retinal detachment masquerading as exudative panuveitis with intense anterior chamber inflammatory reaction. [PDF]
Purpose:This is a retrospective case report illustrating the diagnostic and therapeutic challenges associated with a chronic rhegmatogenous retinal detachment masquerading as a severe panuveitis with intense anterior chamber inflammation.
Bhisitkul, Robert B +3 more
core
This clinical practice guideline from the Explosive Weapons Trauma Care Collective (EXTRACCT) group reviews current best practice for the management of ocular trauma in conflict‐affected regions, where explosive weapons are used and healthcare infrastructure is limited.
Emma Butterfield +8 more
wiley +1 more source
Purpose: This is a retrospective, observational case series of 43 patients who underwent Descemet’s striping automated endothelial keratoplasty with implants of hydrophilic acrylic intraocular lenses with hydrophobic surface (Lentis LS-302-Y or Lentis L ...
Urszula Kołodziejska +6 more
doaj +1 more source
Dead bag syndrome: a suspicious bilateral case [PDF]
Dead bag syndrome is one of the recently described causes of late intraocular lens dislocation. Its etiology is not yet fully understood, but it is related to the reduction or disappearance of lens epithelial cells with subsequent disaggregation of the ...
Mário César Bulla +4 more
doaj +1 more source
Barnes Hospital Bulletin [PDF]
https://digitalcommons.wustl.edu/bjc_barnes_bulletin/1109/thumbnail ...
core +1 more source
A review of angle kappa and multifocal intraocular lenses and their effect on visual outcomes
Abstract Although most patients are satisfied with their vision after multifocal intraocular lens (IOL) implantation, dissatisfaction has been reported for various reasons, including poor visual outcomes and visual disturbances. Many published reports hypothesise that preoperative angle kappa may be an associated factor in patient dissatisfaction ...
Thomas Kohnen +2 more
wiley +1 more source
Comparison of capsular and uveal compatibility between acrylic hydrophobic and hydrophilic intraocular lens for cataract surgery [PDF]
Objective: To assess the difference in the uveal and capsular compatibility between two commonly used intraocular lens materials in patients with phacoemulsification with intraocular lens implant. Methodology: This quasi experimental study included 100
Haroon Tayyab +2 more
doaj
AIM: To estimate the prevalence and causes of blindness and visual impairment in the population aged 40 years and over in Muyuka, a rural district in the South West Province of Cameroon.
Befidi-Mengue, R +4 more
core +2 more sources
A proposed rapid methodology to assess the prevalence and causes of blindness and visual impairment.
PURPOSE: To determine whether a sample of the 50-year-old and above population would provide comparable information to a total population-based survey. METHODS: In 1996, a national eye survey of the total population in The Gambia was undertaken and the ...
Dineen, Brendan +2 more
core +1 more source

