Results 81 to 90 of about 5,555,258 (227)
Abstract Objective To report preliminary results of MP‐TSCP in canine patients with glaucoma while evaluating sweep velocity, treatment efficacy, and safety utilizing standardized surgical parameters. Animal studied Client‐owned dogs that underwent MP‐TSCP at a veterinary referral hospital. Procedure Medical records of 19 eyes (14 dogs) treated with MP‐
Valeria Benitez‐Vera +2 more
wiley +1 more source
Biocompatibility of Intraocular Lenses [PDF]
The performance of an intraocular lens is determined by several factors such as the surgical technique, surgical complications, intraocular lens biomaterial and design, and host reaction to the lens.
Özyol, Pelin +5 more
core +1 more source
IntroductionThis study aimed to develop and validate a novel formula for calculating intraocular lens (IOL) refractive power based on Gaussian optics and thick-lens imaging.MethodsThis study was conducted at Ningbo Traditional Chinese Medicine Hospital ...
Mengdi Yan, Juntao Zhang, Shiming Wang
doaj +1 more source
Abstract Purpose To describe the clinical features surgical technique, early and long‐term outcome with or without surgery, and histopathological findings of melanocytic anterior uveal lesions in young dogs. Methods Medical records of dogs at a guide dog facility removed from training due to a pigmented iris lesion were reviewed from 2014 to 2021 ...
Valerie Liliane Dufour +6 more
wiley +1 more source
Purpose: To evaluate long-term refractive, visual outcomes and patient satisfaction following capsular bag implantation of a multifocal toric intraocular lens (IOL). Setting: Department of Ophthalmology, Professor K. Gibinski University Clinical Center,
Agnieszka Malec-Pleskacz +2 more
core +1 more source
PLA and PCL ocular implants prepared by tape casting and electrospinning provide sustained dexamethasone release with distinct release profiles governed by polymer type and processing method. The relationship between polymer structure, degradation behavior, and drug release demonstrates the potential of these fabrication techniques for controlled ...
Renata Bochanoski +6 more
wiley +1 more source
Background Posterior chamber phakic intraocular lens are widely recognized as an effective treatment for refractive errors, yet they are not without risks.
Shuaishuai Liu, Yong Liu
doaj +1 more source
Considerations of a thick lens formula for intraocular lens power calculation
Background: In recent years, some lens manufacturers have committed to providing lens shape data for some of their lens models. The purpose of this study is to present a strategy for prediction of intraocular lens power and residual refraction based on a
Achim Langenbucher +6 more
doaj +1 more source
Intraocular lens power calculation after radial keratotomy and LASIK - A case report
Purpose: To report a challenging intraocular lens (IOL) power calculation case who received both radial keratotomy (RK) and laser-assisted in situ keratomileusis (LASIK).
Chun-Fu Liu +4 more
doaj +1 more source
Optical‐Field Engineering and Instrumentation in Brillouin Microscopy
Brillouin microscopy provides label‐free mechanical contrast through gigahertz light–acoustic interactions. This Review examines how optical‐field engineering and instrument architecture shape spectral precision, acquisition throughput, background rejection, spatial performance, and optical exposure.
Kangwen Tong +5 more
wiley +1 more source