Results 51 to 60 of about 2,906,862 (241)

Intraoperative recurrent laryngeal nerve monitoring in unconventional thyroid surgery

open access: yesClinical Case Reports, 2022
The most common surgical risk after total thyroidectomy remains the recurrent laryngeal nerve (RLN) injury. Nowadays, the use of intraoperative nerve monitoring systems (IONM) such as the endotracheal tube‐based is recommended to prevent RLN palsy.
Carta Filippo   +6 more
doaj   +1 more source

Intraoperative Neurophysiological Monitoring in Thyroid Operations as a Method of Reducing Neurological Deficit

open access: yesPielęgniarstwo Neurologiczne i Neurochirurgiczne, 2023
Introduction. Intraoperative neuromonitoring consists in current stimulation of the laryngeal nerve located near the thyroid gland. The intensity is usually set in the range of 1–2 mA in order to give the desired effect, but also to give the selectivity ...
Dawid Pilewski, Edyta Zomkowska
doaj   +1 more source

Rapid In Vitro Pathological Diagnosis of Glioma Using Dual‐Color Quantum Dot Probes for Precise Intraoperative Resection

open access: yesAdvanced Science, EarlyView.
Glioma resection surgery is challenging because of the infiltrative growth of the tumor into nearby tissue and the different surgical requirements for gliomas with different mutation types. To improve the precision and effectiveness of glioma resection, this study developed a new imaging probe that enables the tumor boundary and mutation status to be ...
Dongdong Wu   +12 more
wiley   +1 more source

AI‐Assisted Recognition of Actual Ureteral and Pancreatic Injuries in Laparoscopic Colorectal Surgery: A Randomized Video Review Study

open access: yesAnnals of Gastroenterological Surgery, EarlyView.
AI‐generated anatomical highlighting improved surgeons' recognition of actual ureteral injuries during laparoscopic colorectal surgery, including recognition within predefined injury time‐code windows. No significant overall improvement was observed for pancreatic injury, and incorrect adverse‐event judgments did not increase in no‐injury videos. These
Shunjin Ryu   +9 more
wiley   +1 more source

Midline Facial Nerve Monitoring: Single-Center Experience and Review of Literature

open access: yes, 2022
Background: Facial nerve monitoring system has enabled facial muscle activity detection using electrodes placed over the target muscles. In an effort to enable the best and minimally invasive surgical approach, a midline facial nerve monitor was applied ...
Eman A. Hajr   +3 more
core   +1 more source

Thermally Drawn Bioelectric Catheters: Enabling Proprioceptive Endovascular Navigation

open access: yesAdvanced Intelligent Systems, EarlyView.
This work introduces a novel bioelectric navigation system eliminates the need for harmful fluoroscopy during endovascular surgeries. A bespoke 16‐electrode catheter is fabricated using rapid thermal drawing and laser micro‐machining. Paired with a real‐time tracking algorithm fusing vascular geometry detection and distance estimation, this technology ...
Alex Ranne   +8 more
wiley   +1 more source

Neuromonitoring – still highly controversial

open access: yesStudia Medyczne, 2021
Recurrent laryngeal nerve (RLN) paralysis, although rare, is among the most serious complications of thyroid gland surgery. It effects the quality of life of the patient, increases the costs of hospitalization, and can be the cause of legal proceedings ...
Piotr Bryk, Stanisław Głuszek
doaj   +1 more source

Dose‐related propofol resistance in COVID‐19 patients: Altered drug plasma levels, mechanistic insights from neuronal‐derived extracellular vesicles and miRNA analysis

open access: yesBritish Journal of Clinical Pharmacology, EarlyView.
Abstract Aim Critical care for COVID‐19 patients presents unique challenges, particularly in sedation management. Patients demonstrate notable dose‐related resistance to propofol, potentially due to complex pharmacokinetic alterations. Emerging evidence suggests that plasma extracellular vesicle‐associated miRNA represents valuable predictive ...
Debora Curci   +10 more
wiley   +1 more source

Can the use of intraoperative intact parathyroid hormone monitoring be abandoned in patients with hyperparathyroidism? [PDF]

open access: yes, 2013
Background Ultrasound (US) and technetium-99m sestamibi scintigraphy (MIBI) are used to determine the localization of abnormal glands in cases of primary hyperparathyroidism (PHPT).
Minami, Shigeki   +6 more
core   +1 more source

Effects of intravenous methylprednisolone on intraoperative neurophysiological monitoring during spinal cord tumor surgery: a case report [PDF]

open access: yes, 2019
In spinal cord tumor surgery, muscle motor-evoked potentials (mMEPs) and direct wave (D-wave) have been used to predict neurological outcomes. A severe deterioration of mMEPs in the presence of intact D-wave may indicate temporary postoperative weakness.
박윤길, 박진영, 조용은
core   +1 more source

Home - About - Disclaimer - Privacy