Results 91 to 100 of about 407,589 (299)
Background CAD/CAM zirconia barriers represent an advanced option for guided bone regeneration (GBR) in three‐dimensional defects, integrating mechanical stability, biocompatibility, and digital precision. The objectives of this case series were to evaluate, clinically, histologically, and three‐dimensionally, the use of customized zirconia barriers ...
Roberto Ledergerber +5 more
wiley +1 more source
ASSESSMENT OF ACCURACY OF SCANNABILITY AND THE EFFECT OF SURFACE ROUGHNESS ON POLYMETHYLMETHACRYLATE INTRA-ORAL SCAN BODY: IN VITRO STUDY [PDF]
Background: This study aims to create a cost-effective, custom-made intraoral scan body using digital dentistry techniques and to compare its scannability with that of a manufacturer-provided scan body.
Zeyad hussein +3 more
doaj +1 more source
Objectives There are no in vivo studies comparing multiple intraoral scanners for the completely edentulous maxilla to PVS impressions. Investigations comparing intraoral scanners to polyvinyl siloxane impressions focus on comparing the overall scan and ...
Evans, Jane L +3 more
core +1 more source
Volumetric stability and patient‐reported outcomes after soft‐tissue augmentation: A case series
Abstract Background The purpose of this study was to evaluate the 2‐year volumetric stability and patient‐reported outcomes following peri‐implant soft‐tissue augmentation with a porcine acellular dermal matrix. Methods This prospective case series included patients requiring implant‐supported rehabilitation with buccal peri‐implant soft‐tissue ...
Roberta Di Battista +5 more
wiley +1 more source
Assessment of Operator Experience on the Accuracy and Time Required for Intraoral Scanning with Three Different Scanners: A Prospective Study [PDF]
Introduction: Digital workflows in orthodontics increasingly rely on Intraoral Scanning (IOS) due to their advantages in efficiency, patient comfort, and precision. However, the impact of operator experience on scan performance remains a critical factor,
Amritha Nehru, Ravindrakumar Jain
doaj +1 more source
Flexible Direct‐Conversion X‐Ray Detectors: From Emerging Materials to Conformal Imaging
This comprehensive review analyzed the performance, challenges, and future directions of four emerging material systems for next‐generation flexible direct‐conversion X‐ray detectors: organic semiconductors, perovskites, metal–organic frameworks, and inorganic metal compounds.
Haipeng Di +11 more
wiley +1 more source
Statement of problem: The accuracy of digital implant scans can be affected by the implant angulation, implant depth, or interimplant distance. However, studies analyzing intraoral scanning accuracy with different implant angulations and different scan ...
Revilla-León, Marta +6 more
core +1 more source
Validation of Virtual Reality Simulations for Anatomical Landmarks in Panoramic Radiographs
ABSTRACT Objective This study assessed the validity of panoramic anatomical virtual reality (VR) software among senior dental students. Materials and Methods A total of 79 fourth‐year dental students were randomly divided into two groups in this crossover study. Students’ knowledge of panoramic anatomical landmarks was tested.
Daniah M. Alhazmi +4 more
wiley +1 more source
Evaluating Flexure of the Mandible on Opening as Captured by Intraoral Scanners [PDF]
Aims: The mandible flexes on opening, constricting the width in the transverse dimension. Digital intraoral scanners require the patients’ mandible to approach maximum opening during capture. This study compares positional changes of teeth as captured by
Rich, Josiah
core +1 more source
Immersive Technologies in Dental Education: Global Adoption Patterns From a 2025 Survey
ABSTRACT Purpose/Objectives Dental education is undergoing a digital transformation, yet the adoption of immersive technologies such as haptic virtual reality (HVR) remains limited. This study aimed to map global adoption trends, barriers, and opportunities for equitable integration of HVR in dental curricula.
Barry Quinn +28 more
wiley +1 more source

