Example of a 3D scan and the associated 2D intraoral images.
The left side shows a completely scanned lower dental arch, the right side excerpts of this 3D scan in a mesial-lateral and distal-lateral view of tooth 36 with the associated 2D intraoral images at baseline (T1).
Carolina Ganss (755047) +4 more
core +1 more source
Accuracy of CAD/CAM Digital Impressions with Different Intraoral Scanner Parameters
The advancement of intraoral scanners has allowed for more efficient workflow in the dental clinical setting. However, limited data exist regarding the accuracy of the digital impressions produced with various scanner settings and scanning approaches ...
Asher Chiu +3 more
doaj +1 more source
Purpose: To assess the influence of the scan body geometry bevel location and implant angulation and position of complete-arch implant digital scans.
Revilla-León, Marta +13 more
core +1 more source
Influence of age, training, intraoral scanner, and software version on the scan accuracy of inexperienced operators [PDF]
PURPOSE To evaluate the effect of operator age on the scan accuracy (trueness and precision) of inexperienced operators when compared with experienced operators, and how training, intraoral scanner (IOS), and software version affect scan accuracy ...
Karasan, Duygu Narin +13 more
core +1 more source
Comparing the trueness of seven intraoral scanners and a physical impression on dentate human maxilla by a novel method [PDF]
Intraoral scanner (IOS) accuracy is commonly evaluated using full-arch surface comparison, which fails to take into consideration the starting position of the scanning (scan origin).
Evans, Zachary +5 more
core +1 more source
The purpose of this paper was to introduce a method for creating a digital virtual patient by combining cone-beam computed tomography (CBCT), intraoral scan, and facial scan with a high accuracy of integration.
Kim, Jong Cheol +11 more
core +1 more source
Trueness of digital implant impressions based on implant angulation and scan body materials
Effects of implant angulation on digital implant impression accuracy remain controversial. Therefore, this in vitro study aimed to compare the digital implant impression trueness among models with different implant angulations and scan body materials ...
Jae-Hyun Lee, Jae-Hwi Bae, Su Young Lee
doaj +1 more source
Effect of intraoral scanner and fixed partial denture situation on the scan accuracy of multiple implants: An in vitro study. [PDF]
BACKGROUND Accuracy of intraoral implant scans may be affected by the region of the implant and the type of the intraoral scanner (IOSs). However, there is limited knowledge on the scan accuracy of multiple implants placed for an implant-supported ...
Abou-Ayash, Samir +11 more
core +2 more sources
Purpose of this in vitro study was to determine the accuracy of different intraoral scans versus laboratory scans of impressions and casts for the digitization of an edentulous maxilla.A PEEK model of an edentulous maxilla, featuring four hemispheres on the alveolar ridges in region 13, 17, 23 and 27, was industrially digitized to obtain a reference ...
Panagiotis Kontis +3 more
openaire +2 more sources
Congruence between the meshes of a combined healing abutment-scan body system acquired with four different intraoral scanners and the corresponding library file: an in vitro analysis. [PDF]
OBJECTIVES To investigate the congruence between the meshes of a combined healing abutment-scan body (CHA-SB) system acquired with four different intraoral scanners and the corresponding library file.
Marques, Vinicius Rizzo +14 more
core +2 more sources