Results 171 to 180 of about 58,739 (282)
ABSTRACT Aim To evaluate clinical feasibility of 3D‐printed, patient‐specific, polycaprolactone (PCL) resorbable scaffolds for staged alveolar ridge augmentation. Materials and Methods Ten patients requiring staged bone augmentation underwent digital planning to virtually reconstruct the defect to its original contour.
Jamil Alayan +2 more
wiley +1 more source
ABSTRACT Aim To compare peri‐implant soft‐tissue dimensional changes following wound closure using a suture‐free healing abutment attachment (HAA) compared to conventional suturing during implant surgery. Materials and Methods Thirty patients who were randomly allocated to the HAA group (15 patients, 20 implants) or the suture group (15 patients, 15 ...
Seulbin Im +7 more
wiley +1 more source
Effect of ambient light level on scanning accuracy and duration of intraoral scanners: a clinical evaluation. [PDF]
Turgut M, Kaplan MH, Eroglu Z, Kaya B.
europepmc +1 more source
Accuracy of Three Different Strategies for Virtual Interocclusal Registration: An In Vitro Study
ABSTRACT Objective The aim of this study was to compare the accuracy of three different strategies for virtual interocclusal registration in a fully dentate in vitro model. Materials and Methods Three strategies for virtual interocclusal registration were compared: bilateral buccal registration, unilateral buccal registration, and anterior registration.
Ragai Edward Matta +4 more
wiley +1 more source
An in-vitro study on factors influencing the accuracy of current intraoral scanners. [PDF]
Buhl J, Mehl A, Ender A.
europepmc +1 more source
In Vitro Evaluation of Bond Strength of Adhesive Systems to Dentin and Stability of the Hybrid Layer
ABSTRACT Objective Contemporary dental adhesives demonstrate strong durable adhesion to enamel while long‐term bonding stability to dentin remains uncertain. This in vitro study aimed to compare conventional dentin conditioning protocols supplemented with protease inhibition and chelate‐based conditioning protocols. Materials and Methods Four groups of
Ana Torres Muñoz +4 more
wiley +1 more source
Are Conventional Impressions Obsolete? A Narrative Review on the Applicability of Intraoral Scanners. [PDF]
Baradee AA, Spies BC.
europepmc +1 more source
ABSTRACT Objective To compare the surface roughness, color stability, and translucency of zirconia produced by additive manufacturing (AM) and subtractive manufacturing (SM) after exposure to cigarette smoking. Materials and Methods A total of 60 disc‐shaped specimens were fabricated from 2 methods: AM (INNI Cera BCM W500/1000) and SM (VITA YZ T).
Bengisu Mahmutluoglu +2 more
wiley +1 more source
Trueness of Intraoral Scanners for Edentulous Mandibular Arches With and Without Landmarks. [PDF]
Dessborn FR, Braian M.
europepmc +1 more source
ABSTRACT Objectives To evaluate the effects of alumina airborne‐particle abrasion, glass‐bead airborne‐particle abrasion, and hydrofluoric acid etching of intaglio surfaces on the color difference and translucency of a nano‐hybrid ceramic after cementation to resin abutment specimens, and to analyze the relationships between surface roughness and these
Hyuk‐Joon Lee +3 more
wiley +1 more source

