Results 41 to 50 of about 239,587 (174)
Repairing Cyclodialysis by Riveting: A Flanged Polypropylene Suture
Cyclodialysis causes intraocular lens (IOL) pupillary capture. It requires surgical repair to prevent this risk of IOL pupillary capture. However, since repairing cyclodialysis is often technically difficult, other methods such as barricading by suturing,
Ryosuke Tamiya, Masayuki Akimoto
doaj +1 more source
Penetrating Keratoplasty With Sutureless Intrasclerally Fixated Intraocular Lens
In this retrospective study, we reviewed the use of penetrating keratoplasty with sutureless intrasclerally fixated intraocular lens implantation in a closed anterior chamber in patients with several corneal pathologies and aphakia.The medical records of 6 patients, who underwent the procedure, were reviewed.
Burcu, Kasım, Yusuf, Koçluk
openaire +2 more sources
Additive manufacturing of a hard and biocompatible polymer such as polyetheretherketone allows the fabrication of anatomically relevant applicators for brachytherapy (internal radiotherapy), and the application of radioactivity on these implants according to different patterns allows to modulate the energy dose profiles delivered to tumors. Abstract In
Théophraste Lescot +7 more
wiley +1 more source
Is This Really Sutureless Intrascleral Pocket Technique of Transscleral Fixation? [PDF]
Dear Editor, Cho et al. [1] described the "Sutureless intrascleral pocket technique of transscleral fixation of intraocular lens in previous vitrectomized eyes" in April issue. The authors prepare two scleral pockets with a crescent knife 2 mm from the limbus and opposed 180 degree each other without any conjunctival dissection.
Karadag, Remzi +2 more
openaire +2 more sources
Purpose. To evaluate refractive outcomes, intraocular lens (IOL) power calculation, and IOL position following a novel conjunctiva‐sparing transscleral fixation technique. Methods. Forty‐one eyes of 40 patients managed with a flapless transscleral‐sutured technique were included.
Wei Lou +4 more
wiley +1 more source
Haptic exposure after glued intrascleral haptic fixation
We report a rare case of haptic exposure after glued intrascleral haptic fixation using a modified Yamane technique.A 39-year-old man presented for postoperative follow-up after combined implantation of an artificial iris and glued intraocular lens fixation following blunt ocular trauma.Although the implant was well centered and visual acuity remained ...
M. Noel, B. Pion
openaire +3 more sources
Clinical observation of a modified technique for intrascleral fixation of flanged three-piece foldable intraocular lenses through a Hoffman pocket. [PDF]
PurposeTo present the outcomes of a new technique for intrascleral fixation of a flanged three-piece foldable intraocular lens (IOL) without a conjunctival incision.Materials and methodsWe retrospectively reviewed a consecutive series of 12 eyes of 12 ...
Ye H +8 more
europepmc +2 more sources
Abstract The aim of this article is to discuss how physiology and anatomical background affect the effectiveness of implant‐dependent microinvasive glaucoma surgery (MIGS). First, we provide a micro view of aqueous outflow and tissue behaviour. Second, we review studies exploring the mechanisms of the pressure‐lowering effect of MIGS, as well as tissue
Joanna Jabłońska +4 more
wiley +1 more source
Uveal melanoma (UM) is the most common primary intraocular malignancy in adults. DNA repair genes play a vital role in cancer development. However, there has been very little research about DNA repair genes in UM. This study aimed to evaluate the importance of DNA repair genes and established a signature for predicting prognosis and immune features of ...
Tao Wang +7 more
wiley +1 more source
Novel Sutureless Scleral Fixated IOL for Inadequate or Absent Capsular Support
Purpose. To evaluate the clinical outcome and safety profile of a new sutureless scleral fixation (SSF) technique using a single‐piece foldable acrylic Carlevale intraocular lens. Methods. In this case study, 27 eyes of 27 patients were implanted with an SSF single‐piece IOL because of inadequate or absent capsular support.
Georgios Sidiropoulos +6 more
wiley +1 more source

