Results 81 to 90 of about 1,191,105 (198)
Background The aim of this study is to evaluate the microstructure and microcirculation of regional lymph nodes (LNs) in rectal cancer by using non-invasive intravoxel incoherent motion MRI (IVIM-MRI), and to distinguish metastatic from non-metastatic ...
Xinyue Yang +6 more
doaj +1 more source
Reply to: The Physical Foundation of CSF‐IVIM
Magnetic Resonance in Medicine, EarlyView.
Yoshitaka Bito +4 more
wiley +1 more source
Abstract Background Signal‐to‐noise ratio (SNR) measurements are important for quality assurance, especially when quantitative MRI markers or new hardware are being developed or evaluated. Regions of low signal or assumed uniform signal are used for SNR estimation in a variety of MR image types, but this is unreliable due to spatial heterogeneity of ...
Milica Medved +5 more
wiley +1 more source
Detection of synovial inflammation in the sacroiliac joint space through intravoxel incoherent motion imaging: an alternative to contrast agents [PDF]
PURPOSE: We investigated the diagnostic accuracy of simplified intravoxel incoherent motion (IVIM) imaging for detecting synovial inflammation in the sacroiliac joint (SIJ) in a population with active sacroiliitis.
Aysu Başak Özbalcı +2 more
core +1 more source
intravoxel incoherent motion measurements in the human placenta using echo-planar imaging at 0.5 [PDF]
This paper presents the first in vivo measurements of intravoxel incoherent motion in the human placenta, obtained using the pulsed gradient spin echo (PGSE) sequence. The aims of this study were two-fold.
K R Duncan +9 more
core
Comparison of Intravoxel Incoherent Motion Parameters across MR Imagers and Field Strengths: Evaluation in Upper Abdominal Organs [PDF]
Purpose To determine the reproducibility of intravoxel incoherent motion (IVIM) parameters measured in upper abdominal organs with magnetic resonance (MR) imagers from different vendors and with different field strengths.
Thoeny, Harriet C +4 more
core +1 more source
ABSTRACT Purpose Convolutional neural networks (CNNs) are evaluated for improved and accelerated denoising and Rician bias correction in multi‐b DW images with simultaneous signal modeling. Methods Prostate diffusion images from 46 individuals acquired at 20 linearly distributed b‐values (bmax=2000s/mm2) without averaging were used for self‐supervised ...
Mustafa Abbas +4 more
wiley +1 more source
Supplemental Material for Detecting impaired function of renal allografts at the early stage after transplantation using intravoxel incoherent motion imaging by Lihua Chen, Tao Ren, Panli Zuo, Yingxin Fu, Shuang Xia and Wen Shen in Acta ...
Lihua Chen (141443) +5 more
core +1 more source
ABSTRACT Purpose The clinical feasibility and translation of many advanced quantitative MRI (qMRI) techniques are inhibited by their restriction to ‘research mode’, due to resource‐intensive, offline parameter estimation. This work aimed to achieve ‘clinical mode’ qMRI, by real‐time, inline parameter estimation with a trained neural network (NN) fully ...
Samuel Rot +13 more
wiley +1 more source
23Na‐MRI at 3 T was applied to estimate TSC in patients with kidney tumours of different pathologies, which are indistinguishable on conventional imaging methods. The apparent TSC was significantly higher in renal oncocytomas (benign) compared to chromophobe renal cell carcinomas (malignant): 162 ± 58 mM vs. 71 ± 2 mM (p < 0.05).
Ines Horvat‐Menih +16 more
wiley +1 more source

