Results 11 to 20 of about 1,686,605 (255)

A testing device for intrinsically safe multi-circuit protection power supply

open access: yesGong-kuang zidonghua, 2018
In order to solve problems of inconvenient operation, complicated process and low accuracy of existing test methods of intrinsically safe power supply, a testing device for intrinsically safe multi- circuit protection power supply was designed.
REN Gaojian   +3 more
doaj   +3 more sources

A novel chopping current protection circuit for intrinsically safe power supply

open access: yesGong-kuang zidonghua, 2016
For problems that traditional chopping current protection circuit had small cut-off current value and poor anti load impact ability, and needed additional recovery circuit or manual circuit after over-current fault, a novel chopping current protection ...
FANG Xupeng   +4 more
doaj   +3 more sources

Transient analysis of surge immunity test for intrinsically safe sensor

open access: yesGong-kuang zidonghua, 2018
For problem that it was difficult to achieve evaluation grade A due to a long time reverse gap in DC power port voltage of intrinsically safe sensor in positive surge immunity test, taking a typical mine-used intrinsically safe methane sensor as research
ZHANG Ziliang
doaj   +2 more sources

Design Requirements of Lithium Battery in Intrinsically Safe Circuit

open access: yesGong-kuang zidonghua, 2010
The paper introduced safety performance requirements of lithium battery and design requirements of battery and battery pack in intrinsically safe circuit at home and abroad,analyzed common problems in designing battery of intrinsically safe circuit and ...
WANG Qi, WANG Chu
doaj   +1 more source

Design of novel intrinsically safe power supply with 'ia' grade

open access: yesGong-kuang zidonghua, 2017
According to working condition of mine-used power supply in coal mine underground, novel intrinsically safe power supply with 'ia' grade was designed. The power supply uses a fully enclosed AC-DC module to eliminate special flameproof enclosure, and has ...
YU Zhixue, FANG Xupeng, ZHAO Yang
doaj   +2 more sources

Development of mine-used intrinsically safe equipment monitoring substation based on wireless communicatio

open access: yesGong-kuang zidonghua, 2017
In view of poor real-time performance and complex wiring existed in traditional operating condition monitoring of coal mine mechanical and electrical equipment, a mine-used intrinsically safe equipment monitoring substation based on wireless ...
DU Yan   +7 more
doaj   +2 more sources

Design of Intrinsically Safe Power Supply Based on Two-phase Synchronous Boost Technology

open access: yesGong-kuang zidonghua, 2011
In view of problem of bigger output ripper existed in intrinsically safe power supply based on single-phase synchronous boost technology, the paper proposed a design scheme of intrinsically safe power supply based on two-phase synchronous boost ...
ZHANG Xing-hua   +5 more
doaj   +1 more source

Optimization Design of Intrinsic Safety Pilot Circuit for Motor Remote Start and Stop

open access: yesMeikuang Anquan, 2020
This paper introduces the types of remote starting and stopping pilot circuits of existing motors, the existence of mis-starting, the inability to identify all line faults and the unstable operation of power supply voltage reduction, and proposes an ...
ZHANG Yuxiang, SONG Jiancheng, TIAN Muqin
doaj   +1 more source

Safety analysis of half wave oscillator structure in underground 5G radiation field

open access: yesGong-kuang zidonghua, 2023
GB 3836.1-2021 Explosive atmospheres - Part 1: Equipment-General requirements stipulates that the RF threshold power of RF equipment in explosive environments shall not exceed 6 W.
TIAN Zijian   +4 more
doaj   +1 more source

Sensitivity analysis of IEC spark test apparatus

open access: yesMeikuang Anquan, 2021
The sensitivity of spark test apparatus is affected by environmental factors, tungsten wire electrode and cadmium disk electrode. In this paper, the intersection / separation trajectories of tungsten wire electrode and cadmium disk electrode in a test ...
ZHANG Yong
doaj   +1 more source

Home - About - Disclaimer - Privacy