Results 221 to 230 of about 1,686,605 (255)
Some of the next articles are maybe not open access.

Lightning and surge protection in intrinsically safe measuring circuits

R. STAHL Ex Magazine, 2021
Processing or transporting combustible substances can often lead to the creation of mixtures capable of forming an explosive atmosphere. Strict safety precautions must be in place when setting up and operating systems in which substances of this kind may be present. This is also set out in Directive 1999/92/EC [1], which addresses the user or employer.
openaire   +1 more source

Design of embedded fuel sensor based on intrinsically-safe circuit

2017 Chinese Automation Congress (CAC), 2017
The accurate measurement of fuel level plays a significant role in the cruise time and safety performance of aircraft. Capacitive sensors are currently used to measure fuel level in many aircrafts. In order to reduce the wall destruction of fuel tank and solve the problem of intrinsically safety, researchers introduce a new capacitive sensor, based on ...
Mei Yuan   +3 more
exaly   +2 more sources

Numerical simulation of output short-circuit capacitor discharge of intrinsically safe switching transistor converter

2022 IEEE 5th International Electrical and Energy Conference (CIEEC), 2022
Dangshu Wang   +6 more
exaly   +2 more sources

Study on Non-Explosive Assessing System for Intrinsically Safe Circuit

2009 International Conference on Information Engineering and Computer Science, 2009
Due to the advantages of the intrinsically safe circuit, people are increasingly willing to make use of it in comprehensive automatization system and communication equipment. If practical non-explosive testing methods can be constructed base on discharge theory of intrinsically safe circuit, the designers will find it easier to grasp the performance of
Jian-hua Liu   +4 more
exaly   +2 more sources

Equivalent Simple-Inductive-Circuit and Its Applications of Inner Intrinsically Safe Buck Converter

2016 International Symposium on Computer, Consumer and Control (IS3C), 2016
To obtain the Equivalent Simple-Inductive-Circuit (ESIC) and the equivalent-inductance evaluating the inner intrinsic safety performance of the Buck Converter. The Inductor-Disconnected Arc Discharge (IDAD) behaviour of Inner intrinsically Safe Buck Converter (IISBC) is analyzed, and the equivalent-inductance expression is deduced according to the ESIC
Shu-Lin Liu, Yue-Yun Han, Li-Li Qi
openaire   +1 more source

Energy and Power Criterion of Intrinsically Safe Circuits for Explosive Atmospheres

2011
Arc discharge time(T) is determined to be in proportion to time constant(1) based on current linear attenuation model for intrinsically safe inductive circuits. It draws conclusions that maximum value of arc power(Pmax) is in proportion to arc energy(Wg) and is inverse to time constant (1).The conflicting fact that greater sparks can not cause gas ...
openaire   +1 more source

Design and Implementation of a Spark Pulse Power Control Device for Intrinsically Safe Circuits

Journal of Nanoelectronics and Optoelectronics
This paper presents the study and design of a control device capable of adjusting and monitoring spark pulse power and pulse width time. This device aids in the experimental analysis of spark discharge ignition mechanisms and explores the relationship between the spark power, discharge time, and energy. The device comprises two stages. The first stage
Meng-Ran You, Shu-Lin Liu, Dan-Dan Xu
openaire   +1 more source

The Criterion of Intrinsic Safe Circuit Characteristic Based on Electric Arc Power

2011
Intrinsic safety electric equipments are commonly used in coal wells . Because intrinsic safety electric equipments have not the flameproof shell, the determinacy whether the electric arcs can ignite gas becomes the important investigated subject . The energy criterion takes the minimum burning energy as standard.
openaire   +1 more source

Determining the switching speed for the assessment of intrinsically safe circuits

2016
Statistical characteristics of the sample of switching rate are defined. Atswitching rate on spark test apparatus of type I up to 0,5 km/s the density isdistributed according to the log-normal law, and above 0,5 km/s conforms with the gamma density.
openaire   +1 more source

Energy Analysis of Short Circuit Discharge for Composite Intrinsically Safe Circuits

2024 7th International Conference on Mechatronics and Computer Technology Engineering (MCTE)
Pengcheng Xue   +5 more
openaire   +1 more source