Results 161 to 170 of about 54,943 (224)

Cross-field airway management for distal postintubation stenosis: a case of successful reconstruction without ECMO support. [PDF]

open access: yesJ Cardiothorac Surg
Nájera-Acuña CD   +5 more
europepmc   +1 more source

Comparative analysis of a 3D-printed videolaryngoscope versus the Macintosh model in adult airway management: a randomized clinical trial. [PDF]

open access: yesBraz J Anesthesiol
Mendes FF   +14 more
europepmc   +1 more source

Management of infraglottic airway traumatic bleeding using rigid endoscope. [PDF]

open access: yesJ Anaesthesiol Clin Pharmacol
Paliwal S, Utkarsh U, Samagh N, Gupta V.
europepmc   +1 more source
Some of the next articles are maybe not open access.

Related searches:

Direct digital intratracheal intubation for neonatal resuscitation

The Journal of Pediatrics, 1968
Summary The technique of digital introduction of endotracheal tubes for neonatal resuscitation is easy to learn, requires simple and dependable equipment, and has few dangers and limitations. Proficiency in the method allows the unaided physician quickly and easily to establish and use a patent airway for neonatal ...
N C, Woody, H B, Woody
openaire   +2 more sources

Continuous Calculation of Intratracheal Pressure in Tracheally Intubated Patients

Anesthesiology, 1993
Intratracheal pressure (Ptrach) should be the basis for analysis of lung mechanics. If measured at all, Ptrach is usually assessed by introducing a catheter into the trachea via the lumen of the endotracheal tube (ETT). The authors propose a computer-assisted method for calculating Ptrach on a point-by-point basis by subtracting the flow-dependent ...
Guttmann J   +4 more
openaire   +3 more sources

Intratracheal stent intubation under extracorporeal lung assist

Surgery Today, 1995
An artificial stent was intubated using extracorporeal lung assist (ECLA) in two patients with inoperable tracheal stenosis. In a patient with an endotracheal tumor, an airway obstruction due to a partial stent collapse was overcome by an immediate ECLA perfusion.
S, Ishikawa   +5 more
openaire   +2 more sources

[Intratracheal intubation using a fiberoptic laryngoscope].

Annales francaises d'anesthesie et de reanimation, 1991
Experience with a new type of laryngoscope (Bullard) is reported. It weighs 1,200 kg, and has fiberoptic fibers both for lighting and viewing. Angle of vision is about 55 degrees. Endotracheal intubation with this device requires a semi-rigid stylet to bend the tracheal tube at 90 degrees just above its cuff, so as to reproduce the curvature of the ...
B, Riou, O, Langeron, E, Fabas, P, Viars
openaire   +1 more source

Home - About - Disclaimer - Privacy